Standard Practice for Operating the Severe Wastewater Analysis Testing Apparatus
Automaticky přeložený název:
Standardní praktiky pro provoz těžkou odpadních vod Analysis testovací přístroje
NORMA vydána dne 1.10.2013
Označení normy: ASTM G210-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2013
Kód zboží: NS-57612
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
accelerated testing, biogenic sulfide corrosion, hydrogen sulfide gas, protective coatings, protective linings, severe wastewater analysis tests, sewer corrosion, sewer gases, sewer testing, test chambers, wastewater, wastewater gases, ICS Number Code 13.060.30 (Sewage water)
Significance and Use | ||||||||||||||||||||||||||||||||||||
5.1 Domestic wastewater headspace environments are corrosive due to the presence of sewer gases and sulfuric acid generated during the biogenic sulfide corrosion process.5.2 The results obtained by the use of this practice can be a means for estimating the protective barrier qualities of a protective coating or lining for use in severe sewer conditions. 5.3 Some protective coatings or linings may not withstand the exposure temperature specified in this practice but have demonstrated satisfactory performance in actual sewer exposures, which are at lower temperatures. |
||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||
1.1 This practice covers the basic apparatus, procedures, and conditions required to create and maintain the severe wastewater analysis testing apparatus used for testing a protective coating or lining. 1.2 This apparatus may simulate the pertinent attributes of a typical domestic severe wastewater headspace (sewer) environment. The testing chamber comprises two phases: (1) a liquid phase containing a prescribed acid and saline solution, and (2) a vapor phase consisting of air, humidity, and concentrated sewer gas (Note 1). The temperature of the test chamber is elevated to create accelerated conditions and reaction rates. 1.3 Caution—This practice can be extremely
hazardous. All necessary precautions need to be taken when working
with sewer gas, sulfuric acid, and a glass tank. It is highly
recommended that a professional testing laboratory experienced in
testing with hydrogen sulfide, carbon dioxide, and methane gases
perform this practice.
1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific hazards statements are given in Section 8 on Hazards. |
||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||
|