Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specifications and Test Methods for Metallic Angled Orthopedic Fracture Fixation Devices
Automaticky přeložený název:
Standardní Specifikace a zkušební metody pro kovovýrobu Úhlová Ortopedická fixace zlomeniny Devices
NORMA vydána dne 10.11.2000
Označení normy: ASTM F384-00
Poznámka: NEPLATNÁ
Datum vydání normy: 10.11.2000
Kód zboží: NS-55115
Počet stran: 11
Přibližná hmotnost: 33 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
angled devices, bend testing, blade plate, compression hip screw, fatigue test, orthopedic medical devices, surgical devices, surgical implants, ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||
1.1 This standard is intended to provide a comprehensive reference for angled devices used in the surgical internal fixation of the skeletal system. This standard establishes consistent methods to classify and define the geometric and performance characteristics of angled devices. This standard also presents a catalog of standard specifications that specify material and labeling and handling requirements, and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivoperformance of angled devices. 1.2 It is not the intention of this standard to define levels of performance of case-specific clinical performance for angled devices, as insufficient knowledge is available to predict the consequences of their use in individual patients for specific activities of daily living. Futhermore, it is not the intention of this standard to describe or specify specific designs for angled devices used in the surgical internal fixation of the skeletal system. 1.3 This standard may not be appropriate for all types of angled devices. The user is cautioned to consider the appropriateness of this standard in view of a particular angled device and its potential application. 1.4 This standard includes the following test methods used in determining the following angled device mechanical performance characteristics: 1.4.1 Standard test method for single cycle compression bend testing of metallic angled orthopedic fracture fixation devices (see Annex A1). 1.4.2 Standard test method for determining the bending fatigue properties of metallic angled orthopedic fracture fixation devices (see Annex A2). 1.5 Unless otherwise indicated, the values stated in SI units shall be regarded as the standard. Note 1--There is currently no ISO standard that is either similar to equivalent to this standard. |
||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.