Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Cured-in-Place Pipe Lining System for Rehabilitation of Metallic Gas Pipe
Automaticky přeložený název:
Standard Specification pro tvrzených-in-Place Pipe obložení systém pro rehabilitaci kovové plynového potrubí
NORMA vydána dne 1.8.2013
Označení normy: ASTM F2207-06(2013)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.8.2013
Kód zboží: NS-53189
Počet stran: 20
Přibližná hmotnost: 60 g (0.13 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
composite, cured-in-place, flexible tubing, gas pipe renewal, inversion, rehabilitation, ICS Number Code 23.040.15 (Non-ferrous metal pipes)
1. Scope | ||||||||||||||||||||||||||||
1.1 This specification covers requirements and method of testing for materials, dimensions, hydrostatic burst strength, chemical resistance, adhesion strength and tensile strength properties for cured-in-place (CIP) pipe liners installed into existing metallic gas pipes, 3/4 to 48 in. nominal pipe size, for renewal purposes. The maximum allowable operating pressure (MAOP) of such renewed gas pipe shall not exceed a pressure of 300 psig (2060 kPa). The cured-in-place pipe liners covered by this specification are intended for use in pipelines transporting natural gas, petroleum fuels (propane-air and propane-butane vapor mixtures), and manufactured and mixed gases, where resistance to gas permeation, ground movement, internal corrosion, leaking joints, pinholes, and chemical attack are required. 1.2 The medium pressure (up to 100 psig) cured-in-place pipe liners (Section A) covered by this specification are intended for use in existing structurally sound or partially deteriorated metallic gas pipe as defined in 1.2.1 Continued growth of external corrosion, if undetected and unmitigated, could result in loss of the host pipe structural integrity to such an extent that the liner becomes the sole pressure bearing element in the rehabilitated pipeline structure. The CIP liner is not intended to be a stand-alone pipe and relies on the structural strength of the host pipe. The operator must maintain the structural integrity of the host pipe so that the liner does not become free standing. 1.3 MPL CIP liners (Section A) can be installed in partially deteriorated pipe as defined in 1.3.1 HPL CIP liners (Section B) are intended for use only in existing structurally sound steel gas pipe as defined in 1.4 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|
Historická
1.11.2012
Historická
1.11.2013
Historická
1.10.2011
Historická
1.10.2010
Historická
1.10.2010
Historická
1.1.2011
Poslední aktualizace: 03.05.2024 (Počet položek: 2 896 946)
© Copyright 2024 NORMSERVIS s.r.o.