Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Installing Corrugated Steel Structural Plate Pipe for Sewers and Other Applications
Automaticky přeložený název:
Standardní praktiky pro instalaci z vlnité ocelové konstrukční deska potrubí pro kanalizace a dalších aplikací
NORMA vydána dne 1.11.2013
Označení normy: ASTM A807/A807M-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2013
Kód zboží: NS-4323
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
buried structures, installation, sewers, steel pipe, structural plate pipe, ICS Number Code 23.040.15 (Non-ferrous metal pipes)
Significance and Use | ||||||||||||||||||||||
4.1 Structural plate structures function structurally as a flexible ring that is supported by and interacts with the compacted surrounding soil. The soil placed around the structure is thus an integral part of the structural system. It is therefore important to ensure that the soil structure is made up of acceptable material and is well constructed. Field verification of soil structure acceptability using Test Methods D1556, D2167, D6938, or D2937, as applicable, and comparing the results with either Test Methods D698 or D1557, in accordance with the specifications for each project, is the most common basis for installation of an acceptable structure. Depending on the backfill used, other qualitative or performance-based methods acceptable to the engineer may also be used. The required density and method of measurement are not specified by this practice, but must be established in the specifications for each project. |
||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||
1.1 This practice covers procedures, soils, and soil placement for the proper installation of corrugated steel structural plate pipe, pipe-arches, arches, and underpasses produced to Specification A761/A761M, in either trench or embankment installations. A typical trench installation and a typical embankment (projection) installation are shown in 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.3 The values stated in either inch-pound units or SI units shall be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining values in any way. SI units are shown in brackets in the text for clarity, but they are the applicable values when the installation is to be performed using SI units. |
||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||
|
Historická
1.8.2011
Historická
1.4.2012
Historická
1.10.2009
Historická
1.10.2009
Historická
1.10.2013
Historická
1.11.2008
Poslední aktualizace: 06.05.2025 (Počet položek: 2 198 779)
© Copyright 2025 NORMSERVIS s.r.o.