Standard Test Method for Evaluating Thermal EMF Properties of Base-Metal Thermocouple Connectors
Automaticky přeložený název:
Standardní zkušební metoda pro hodnocení Termální EMF vlastnosti základního kovu termočlánkových konektorů
NORMA vydána dne 1.5.2013
Označení normy: ASTM E2820-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2013
Kód zboží: NS-46091
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
connector emf, thermocouple connector, thermocouple contact, thermocouple pin, thermocouple socket, thermocouple terminal, ICS Number Code 17.200.20 (Temperature-measuring instruments)
Significance and Use | ||||||||||||||
5.1 A thermocouple connector, exposed to a temperature difference, contributes to the output of a thermocouple circuit. The output uncertainty allocated to the connector depends on the connector design and temperature gradient. 5.2 Connector performance can be classified based on the results of this method and used as part of a component specification. 5.3 The method can be used as an engineering tool for evaluating different connector designs tested under similar thermal conditions. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This standard describes a thermal emf test method for base-metal thermocouple connectors including Types E, J, K, N and T. Standard connectors such as found in Specifications E1129/E1129M and E1684 as well as non-standard connector configurations and connector components can be evaluated using this method. 1.2 The measured emf is reported as an equivalent temperature deviation or error relative to a reference thermocouple of the same type. This method can be used to verify deviations introduced by the connector greater than or equal to 1°C. 1.3 The connector is tested with thermocouple contacts axially aligned with a temperature gradient using a specified thermal boundary condition. The actual temperature difference developed across the connector and corresponding error will depend on the connector design. 1.4 Connector contacts are often fabricated from raw materials having temperature-emf relationships in accordance with Specification E230. However, verifying Specification E230 tolerances is not within the scope of this method. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Historická
1.11.2011
Historická
1.5.2014
Historická
1.11.2012
Historická
1.4.2013
Historická
1.5.2013
Historická
1.5.2013
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 07.11.2024 (Počet položek: 2 209 910)
© Copyright 2024 NORMSERVIS s.r.o.