Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers (Includes all amendments And changes 6/10/2020).
Automaticky přeložený název:
Standardní praktiky pro kontroly na místě instalovaných Fire společných systémů odporových a Perimeter Fire bariér
NORMA vydána dne 1.9.2015
Označení normy: ASTM E2393-10a(2015)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2015
Kód zboží: NS-615043
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
fire resistive joint system, firestopping, inspection, inspector, joint, joint system,, ICS Number Code 13.220.50 (Fire-resistance of building materials and elements)
Significance and Use | ||||||||||||||||
5.1 This practice is intended to provide a standard set of guidelines that are to be followed when conducting and reporting on inspections of installed fire resistive joint systems. 5.2 This practice is intended to provide a means to verify compliance of the installed fire resistive joint systems to the inspection documents. 5.3 This practice is not intended to provide a basis for selecting installers or products, or both. 5.4 This practice is not intended to establish any performance criteria of the inspected fire resistive joint systems. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice covers the establishment of procedures to inspect fire resistive joint systems, including methods for field verification and inspection. 1.2 This practice addresses all types of fire resistive joint systems and of perimeter joint protection. Note 1: Fire resistive joint system and joint are defined in
Test Method E1966 and
UL 2079.
Note 2: Perimeter joint protection is defined in Test Method
E2307.
Note 3: Fire resistive joint systems include joints between
two fire resistive assemblies, and perimeter joints between a fire
resistive floor assembly and a non-fire-resistive wall assembly.
The application of these systems are sometimes extended based on an
evaluation to other types of construction.
1.3 This practice provides methods by which qualified inspectors verify that required fire resistive joint systems on a project have been installed and that their installations are in accordance with the inspection documents. 1.4 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 27.11.2024 (Počet položek: 2 209 730)
© Copyright 2024 NORMSERVIS s.r.o.