Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for General Techniques of Liquid Chromatography-Infrared (LC/IR) and Size Exclusion Chromatography-Infrared (SEC/IR) Analyses
Automaticky přeložený název:
Standardní praktiky pro všeobecné Techniky kapalinové chromatografie-infračervené (LC / IR) a vylučovací chromatografii-infračervené (SEC / IR) Analýzy
NORMA vydána dne 1.11.2011
Označení normy: ASTM E2106-00(2011)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2011
Kód zboží: NS-44315
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
infrared spectroscopy, LC/IR, liquid chromatography, SEC/IR, Flowcell detection, Infrared (IR) analysis--metals/alloys, LC/IR (liquid chromatography/infrared analysis), Liquid chromatography (LC), Eluent trapping techniques, Qualitative analysis/measurement, Quantitative analysis/measurement, Size-exclusion chromatography (SEC), Software treatment (of infrared data), ICS Number Code 71.040.30 (Chemical reagents)
Significance and Use | ||||||||
This practice provides general guidelines for the practice of liquid chromatography or size exclusion chromatography coupled with infrared spectrometric detection and analysis (LC/IR, SEC/IR). This practice assumes that the chromatography involved is adequate to resolve a sample into discrete fractions. It is not the intention of this practice to instruct the user on how to perform liquid or size exclusion chromatography (LC or SEC). |
||||||||
1. Scope | ||||||||
1.1 This practice covers techniques that are of general use in qualitatively analyzing multicomponent samples by using a combination of liquid chromatography (LC) or size exclusion chromatography (SEC) with infrared (IR) spectrometric techniques. The sample mixture is separated into fractions by the chromatographic separation. These fractions are subsequently analyzed by an IR spectroscopic method. 1.2 Three different types of LC/IR techniques have been used to analyze samples (1, 2). These consist of eluent trapping (see Practices E334), flowcell and direct deposition. These are presented in the order that they were first used. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.4.2010
Historická
1.3.2011
Historická
1.3.2013
Historická
1.4.2010
Historická
1.8.2011
Historická
1.12.2013
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 26.11.2024 (Počet položek: 2 206 223)
© Copyright 2024 NORMSERVIS s.r.o.