Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Measuring and Compensating for Transmittance of an Attenuating Medium Using Infrared Imaging Radiometers
Automaticky přeložený název:
Standardní praxe pro měření a kompenzaci propustnost polehčující média pomocí termovizních Radiometry
NORMA vydána dne 1.12.2014
Označení normy: ASTM E1897-14
Poznámka: NEPLATNÁ
Datum vydání normy: 1.12.2014
Kód zboží: NS-43490
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
attenuating medium, blackbody simulator, emissivity, filter, imaging, infrared, infrared examination, infrared testing, infrared thermography, nondestructive testing, radiometry, reflected temperature, temperature compensation, transmittance, temperature measurement, window,, ICS Number Code 17.200.10 (Heat. Calorimetry)
Significance and Use | ||
5.1 The transmittance of an attenuating medium can cause errors for an infrared thermographer using an infrared imaging radiometer to measure the temperature of a specimen through the medium. Three test methods are given for measuring and compensating for this error source. 5.1.1 A procedure is given for measuring the transmittance of an attenuating medium. 5.1.2 A procedure is given for compensating for errors when measuring the temperature of a specimen having a known emissivity through an attenuating medium with a known transmittance. 5.1.3 A procedure is given for measuring and compensating for transmittance and emissivity errors when the specimen temperature is known. 5.2 These procedures can be used in the field or laboratory using commonly available materials. 5.3 These procedures can be used with any infrared radiometers that have the required computer capabilities. 5.4 The values of transmittance are defined only in terms of the procedure for the purpose of process control and nondestructive evaluation of materials. |
||
1. Scope | ||
1.1 This practice covers procedures for measuring and compensating for transmittance when using an infrared imaging radiometer to measure the temperature of a specimen through an attenuating medium, such as a window, filter or atmosphere.1.2 The values stated in SI units are to be regarded as the standard. 1.3 These procedures may involve use of equipment and materials in the presence of heated or electrically-energized equipment, or both. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Historická
1.9.2013
Historická
1.9.2012
Historická
1.3.2011
Historická
1.11.2010
Historická
15.1.2015
Historická
15.9.2013
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.05.2025 (Počet položek: 2 198 283)
© Copyright 2025 NORMSERVIS s.r.o.