Standard Practice for Qualification of Radioscopic Systems
Automaticky přeložený název:
Standardní praxe pro Kvalifikace skiaskopická systémů
NORMA vydána dne 10.7.2001
Označení normy: ASTM E1411-01
Poznámka: NEPLATNÁ
Datum vydání normy: 10.7.2001
Kód zboží: NS-41666
Počet stran: 12
Přibližná hmotnost: 36 g (0.08 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Compton back-scattered, contrast manipulation, contrast sensitivity, duplex wire gage, edge sharpening, focal detector distance (FDD), focal object distance (FOD), focal spot size, image processor, image quality indicator, imager, line-pair gage, magnification, near real-time radioscopy, noise reduction, penetrating radiation, programmability, radioscopic, radioscopic examination geometry, raster scan, real-time radioscopy, spatial resolution, static mode, step wedge, transmitted beam
| 1. Scope | ||||||||||||||||||||||||||
|
1.1 This practice provides test and measurement details for measuring the performance of X-ray and Gamma ray radioscopic systems. Radioscopic examination applications are diverse. Therefore, system configurations are also diverse and constantly changing as the technology advances. 1.2 This practice is intended as a means of initially qualifying and requalifying a radioscopic system for a specified application by determining its performance level when operated in a static mode. System architecture including the means of radioscopic examination record archiving and the method for making the accept/reject decision are also unique system features and their effect upon system performance must be evaluated. 1.3 The general principles, as stated in this practice, apply broadly to transmitted-beam penetrating radiation radioscopy systems. Other radioscopic systems, such as those employing neutrons and Compton back-scattered X-ray imaging techniques, are not covered as they may involve equipment and application details unique to such systems. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For information on safety requirements, refer to the applicable documents listed in Section 2. |
||||||||||||||||||||||||||
| 2. Referenced Documents | ||||||||||||||||||||||||||
|