Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Evaluating Residential Indoor Air Quality Concerns
Automaticky přeložený název:
Standardní praxe pro hodnocení Obytné Vnitřní obavy o kvalitě ovzduší
NORMA vydána dne 1.4.2014
Označení normy: ASTM D7297-14
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2014
Kód zboží: NS-38100
Počet stran: 28
Přibližná hmotnost: 84 g (0.19 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
biological contaminants, chemical contaminants, HVAC systems, IAQ investigations, indoor air quality (IAQ), indoor materials, indoor sources, measurements, odor, survey, ventilation, water leakage, ICS Number Code 13.040.20 (Ambient atmospheres)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||
5.1 IAQ-based complaints and problems including discomfort/health symptoms and unacceptable indoor environmental conditions such as odors exist in residential buildings, but the frequency of the occurrence of IAQ complaints and problems is not known. 5.2 Characterization of IAQ concerns and identification of their underlying causes require systematic observations and measurements of the indoor environment, its occupants and contaminant sources. This practice provides background and procedures for the investigation of IAQ concerns. 5.3 Where the dwelling is not owner-occupied, formal permission to access certain areas of the property and to collect information essential to the IAQ investigation is often deemed essential to be obtained from the owner and, where applicable, from other tenants. An investigator should seek legal advice in these matters. 5.4 The stepwise and phased approach described in this practice allows for an investigation that is commensurate with the nature of the problem and the level of resources available for the investigation. |
||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This standard practice describes procedures for evaluating indoor air quality (IAQ) concerns in residential buildings. 1.2 The practice primarily addresses IAQ concerns encountered in single-family detached and attached (for example, townhouse or duplex design) residential buildings. Limited guidance is also included for low- and high-rise multifamily dwellings. 1.3 The IAQ evaluation procedures are comprised of interviews with the homeowner or resident(s) (including telephone interviews and face-to-face meetings) and on-site investigations (including walk-through, assessment, and measurements). For practicality in application, these procedures are divided into three separate phases, which may occur over one or more site visits. 1.4 The procedures described in this standard practice are aimed at identifying potential causes contributing to the IAQ concern. Such findings should become a basis for recommending corrective measures. This standard practice does not describe problem resolution or corrective measures and the standard is not intended to evaluate the impact of corrective measures. 1.5 This practice describes a pathway for characterizing indoor air, though adherence to this practice does not guarantee that an investigator will be able to identify or resolve an IAQ complaint for one or more of the following reasons: (1) the diversity of sources and contaminants in indoor air; (2) other factors that may affect occupant perception and acceptance of indoor air quality, such as air temperature, humidity, noise, lighting, and psychological stress; (3) the range of susceptibility in the population. 1.6 Implementation of procedures given in this standard requires the investigator (or investigative team) to have adequate background in several areas: general principles of IAQ; interviewing techniques; building design and construction practices; basic understanding of heating and cooling systems and appliances; use of IAQ measurement equipment; interpretation of IAQ data; and technical report writing. 1.7 Although many elements described in this standard practice may be useful in training of IAQ investigators, it should not be used as the sole basis for specifying or conducting such training. 1.8 This standard does not
purport to address all of the safety concerns, if any, associated
with its use. It is the responsibility of the user of this standard
to establish appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
Standard Test Method for Determining Air
Change in a Single Zone by Means of a Tracer Gas Dilution Standard Test Methods for Determining Air
Leakage of Air Distribution Systems by Fan Pressurization Standard Test Methods for Estimating
Contribution of Environmental Tobacco Smoke to Respirable Suspended
Particles Based on UVPM and FPM Standard Practice for Collection of
Dislodgeable Pesticide Residues from Floors Standard Practice for Reporting Opinions
of Scientific or Technical Experts Standard Practices for Air Leakage Site
Detection in Building Envelopes and Air Barrier Systems Standard Test Methods for Determining
Airtightness of Buildings Using an Orifice Blower Door Standard Guide for Assessing
Depressurization-Induced Backdrafting and Spillage from Vented
Combustion Appliances Standard Guide for Evaluating Water
Leakage of Building Walls ASHRAE 62.2-2010 Ventilation and Acceptable Indoor Air
Quality in Low-Rise Residential Buildings Available from American
Society of Heating, Refrigerating, and Air-Conditioning Engineers,
Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA 30329,
http://www.ashrae.org. Standard Test Method for Determining Air
Leakage Rate by Fan Pressurization Standard Terminology Relating to
Biological Effects and Environmental Fate Standard Test Method for Determination of
Formaldehyde and Other Carbonyl Compounds in Air (Active Sampler
Methodology) Standard Practice for Collection of Floor
Dust for Chemical Analysis Standard Test Method for Determination of
Volatile Organic Compounds in Atmospheres (Canister Sampling, Mass
Spectrometry Analysis Methodology) Standard Guide for the Inspection of
Water Systems for Legionella and the Investigation of Possible
Outbreaks of Legionellosis (Legionnaires' Disease or Pontiac
Fever) Standard Practice for Choosing Sorbents,
Sampling Parameters and Thermal Desorption Analytical Conditions
for Monitoring Volatile Organic Chemicals in Air Standard Test Method for Estimating
Contribution of Environmental Tobacco Smoke to Respirable Suspended
Particles Based on Solanesol Standard Guide for Selection of Methods
for Active, Integrative Sampling of Volatile Organic Compounds in
Air (Withdrawn 2018) Standard Guide for Limiting Water-Induced
Damage to Buildings Standard Terminology Relating to
Pesticides Standard Terminology Relating to Sampling
and Analysis of Atmospheres (Includes all amendments and changes
9/7/2020). Standard Practice for Planning the
Sampling of the Ambient Atmosphere Standard Practice for Sampling and
Selection of Analytical Techniques for Pesticides and
Polychlorinated Biphenyls in Air |
Historická
1.10.2011
Historická
1.4.2013
Historická
1.4.2012
Historická
1.3.2009
Historická
1.4.2008
Historická
1.4.2013
Poslední aktualizace: 21.12.2024 (Počet položek: 2 216 840)