Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Ozone in the Atmosphere: Continuous Measurement by Ethylene Chemiluminescence
Automaticky přeložený název:
Standardní zkušební metoda pro ozón v atmosféře: kontinuální měření ethylenu chemiluminiscencí
NORMA vydána dne 1.4.2008
Označení normy: ASTM D5149-02(2008)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2008
Kód zboží: NS-30036
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
chemiluminescent, continuous analyzer, ethylene, ozone, Atmospheric analysis, Automated procedures--atmospheric analysis, Chemiluminescence detection, Continuous measurement/monitoring--atmospheric analysis, Ethylene chemiluminescence method, Ozone (O3), Photometry--atmospheric analysis, Sampling air/atmospheric materials/applications, ICS Number Code 13.040.20 (Ambient atmospheres)
Significance and Use | ||||||||||||||||||||||||||
Air quality standards for ozone have been promulgated by government authorities to protect the health and welfare of the public. Though ozone itself is a toxic material, it is often complex organic compounds that cause the symptoms of smog such as tearing and burning eyes. However, ozone is the predominant oxidant and is much more easily monitored than organic species. Since ozone concentrations are also correlated with other photochemical oxidant levels, it is the substance that is specified in air quality standards and regulations. |
||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||
1.1 This test method describes the sampling and continuous analysis of the ozone content of the atmosphere at concentrations of 20 to 2000 μg of ozone/m3 (10 ppb (v) to 1 ppm (v)). 1.2 This test method is limited in application by its sensitivity to interferences as described below. This test method is not suitable for personal sampling because of instrument size and sensitivity to vibration and ambient temperature. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Some specific precautionary statements are presented in Section 8. |
||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||
|
Historická
1.4.2008
Historická
1.3.2009
Historická
1.4.2013
Historická
1.4.2010
Historická
1.10.2012
Historická
1.4.2010
Poslední aktualizace: 21.12.2024 (Počet položek: 2 216 840)
© Copyright 2024 NORMSERVIS s.r.o.