Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Water Content and Density of Soil in Place by Time Domain Reflectometry (TDR)
Automaticky přeložený název:
Standardní zkušební metoda pro obsah vody a hustoty půdy na místě Time Domain Reflectometry ( TDR )
NORMA vydána dne 1.5.2005
Označení normy: ASTM D6780-05
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2005
Kód zboží: NS-36510
Počet stran: 13
Přibližná hmotnost: 39 g (0.09 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
compaction test, construction control, density, dielectric constant, electrical permittivity, electromagnetic waves, field control, field tests, inspection, moisture content, quality control, soil compaction, soil density, time domain reflectometry, water content, ICS Number Code 13.080.20 (Physical properties of soil)
1. Scope | ||||||||||||||||||
1.1 This test method may be used to determine the water content of soils and the in-place density of soils using a TDR apparatus. 1.2 This test method applies to soils that have 30 % or less by weight of their particles retained on the 19.0-mm ( 3/4-in.) sieve. 1.3 This test method is suitable for use as a means of acceptance for compacted fill or embankments. 1.4 This test method may not be suitable for organic and highly plastic soils. 1.5 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D 6026. 1.5.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope. 1.6 Two alternative procedures are provided. 1.6.1 Procedure A involves two tests in the field, an in-place test and a test in a mold containing material excavated from the in-place test location. The apparent dielectric constant is determined in both tests. 1.6.2 Procedure B involves only an in-place test by incorporating a bulk electrical conductivity in addition to the apparent dielectric constant. 1.7 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. For additional information consult ASTM SI 10 1,8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Poslední aktualizace: 22.11.2024 (Počet položek: 2 206 568)
© Copyright 2024 NORMSERVIS s.r.o.