Standard Test Method for Determining the Performance of a Sonic Anemometer/Thermometer
Automaticky přeložený název:
Standardní zkušební metodu pro stanovení výkonnost Sonic anemometr / teploměr
NORMA vydána dne 1.4.2015
Označení normy: ASTM D6011-96(2015)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2015
Kód zboží: NS-586202
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
acceptance angle, acoustic pathlength, shadow correction, sonic anemometer, sonic temperature, sonic thermometer, speed of sound, system delay ,, ICS Number Code 17.200.10 (Heat. Calorimetry)
Significance and Use | ||||||||
5.1 This test method provides a standard method for evaluating the performance of sonic anemometer/thermometers that use inverse time solutions to measure wind velocity components and the speed of sound. It provides an unambiguous determination of instrument performance criteria. The test method is applicable to manufacturers for the purpose of describing the performance of their products, to instrumentation test facilities for the purpose of verifying instrument performance, and to users for specifying performance requirements. The acoustic pathlength procedure is also applicable for calibration purposes prior to data collection. Procedures for operating a sonic anemometer/thermometer are described in Practice D5527. 5.2 The sonic anemometer/thermometer array is assumed to have a sufficiently high structural rigidity and a sufficiently low coefficient of thermal expansion to maintain an internal alignment to within the manufacturer's specifications over its designed operating range. Consult with the manufacturer for an internal alignment verification procedure and verify the alignment before proceeding with this test method. 5.3 This test method is designed to characterize the performance of an array model or probe design. Transducer shadow data obtained from a single array is applicable for all instruments having the same array model or probe design. Some non-orthogonal arrays may not require specification of transducer shadow corrections or the velocity calibration range. |
||||||||
1. Scope | ||||||||
1.1 This test method covers the determination of the dynamic performance of a sonic anemometer/thermometer which employs the inverse time measurement technique for velocity or speed of sound, or both. Performance criteria include: (a) acceptance angle, (b) acoustic pathlength, (c) system delay, (d) system delay mismatch, (e) thermal stability range, (f) shadow correction, (g) velocity calibration range, and (1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|
Historická
1.9.2013
Historická
15.3.2014
Historická
1.12.2014
Historická
1.12.2014
Historická
1.10.2014
Historická
1.8.2011
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 02.05.2025 (Počet položek: 2 198 171)
© Copyright 2025 NORMSERVIS s.r.o.