Standard Test Method for Early Stiffening of Hydraulic Cement (Mortar Method)
Automaticky přeložený název:
Standardní zkušební metoda pro ranou vyztužení hydraulický cement (malty Method)
NORMA vydána dne 1.12.2013
Označení normy: ASTM C359-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.12.2013
Kód zboží: NS-13086
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
early stiffening, false set, flash set, hydraulic-cement mortar, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||||||||||||||
5.1 The purpose of this test method is to determine the degree to which a cement mortar develops early stiffening. It is intended for use by those interested in methods for determining the potential early stiffening of hydraulic cement. 5.2 When used for estimating the relative tendency of a cement to manifest early stiffening, a judgment may be made by comparing the behavior in the penetration series (see 5.3 Severe false setting in a cement may cause difficulty from a placing and handling standpoint, but it is not likely to cause difficulties where concrete is mixed for a longer time than usual, as usually occurs in transit mixing, or where it is remixed prior to placing or transporting, in concrete pumping operations. It is most likely noticed where concrete is mixed for a short period of time in stationary mixers and transported to the forms in non-agitating equipment, as on some paving jobs, and when concrete is made in an on-site batch plant. 5.4 Cements with severe false setting usually require slightly more mixing water to produce the same consistency, which may result in slightly lower strengths and increased drying shrinkage. 5.5 Early stiffening resulting from false set is not likely to cause a cement to fail the applicable time of setting requirement. 5.6 Early stiffening resulting from flash set, depending on severity, can cause a cement to fail the applicable time of setting requirement. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of early stiffening in hydraulic-cement mortar. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Warning: Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure.2 1.4 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
15.11.2013
Historická
1.4.2012
Historická
1.4.2012
Historická
1.12.2011
Historická
1.10.2012
Historická
1.12.2011