Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Water-Extractable Sulfate in Hydrated Hydraulic Cement Mortar (Withdrawn 2017)
Automaticky přeložený název:
Standardní zkušební metoda pro vodní extrahovatelné sulfátu v hydratované hydraulické cementová malta
NORMA vydána dne 1.5.2008
Označení normy: ASTM C265-08
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2008
Kód zboží: NS-12736
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
hydraulic cement, optimum sulfate content, sulfate, sulfate content, Calcium sulfate (CaSO4), Cement mortars, Hydraulic cement concrete, Sulfur trioxide (SO3), Water-extractable matter/processing, ICS Number Code 91.100.10 (Cement. Gypsum. Lime. Mortar)
Significance and Use | ||||||||||||||||||||||||
Excess soluble sulfate ions in hardened cement can result in reduced durability. This test method is intended to show whether calcium sulfate has been used in cement in such amount to leave excess soluble sulfate in hardened mortar. The test method is used to establish compliance in Specification C 595 for those cements in which optimized SO3 exceeds the table limit. This test method also can provide useful information on other hydraulic cements, such as those specified in Specifications C 150 and C 1157. When this test method is used in conjunction with Test Method C 563, use the appropriate age of test specimens (24 h, 3 days, or 7 days) to coincide with the age of specimens used in Test Method C 563. |
||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||
1.1 This test method covers the measurement of water-extractable SO3 in hardened hydraulic cement mortar. This measurement is assumed to represent unreacted, available sulfate remaining in the mortar. 1.1.1 Warning—Fresh hydraulic cementious mixtures are caustic and may cause chemical burns to skin and tissue upon prolonged exposure. 1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 Values in SI units were obtained by measurement in SI units or by appropriate conversion using the Rules for Conversion and Rounding given in IEEE/ASTM SI-10 Standard of measurements made in other units. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Poslední aktualizace: 01.11.2024 (Počet položek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.