Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Concrete Sanitary Sewer Pipe by Negative (Vacuum) or Positive Air Pressure
Automaticky přeložený název:
Standardní zkušební metoda pro konkrétní sanitární kanalizační potrubí o negativní (vakuum), nebo tlaku vzduchu Pozitivní
NORMA vydána dne 1.7.2013
Označení normy: ASTM C1618-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.7.2013
Kód zboží: NS-12037
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ICS Number Code 93.030 (External sewerage systems)
Significance and Use | ||||||||
5.1 This is a quality control test performed at the manufacturing plant to establish that the finished, shippable pipe meets the leakage limits stated in the specifications. |
||||||||
1. Scope | ||||||||
1.1 This test method covers procedures for testing of precast concrete pipe sections, prior to delivery, where maximum field leakage rates are specified. 1.2 Tests described in this standard are intended to be used at the point of manufacture of the concrete pipe and are not intended for testing installed pipe (for field tests see Practices C924, C969, and C1214). The user of this specification is advised that individual or multiple pipe sections may be tested for the purpose of testing the pipe barrel and additionally the joints in straight alignment when multiple pipe sections are tested. 1.3 Test times are based on leakage rates and therefore are proportional only to the pipe diameter and are constant for any length of test pipe or pipeline. 1.4 Test times tabulated and the rate of air loss in this standard are based on successful testing of installed pipelines. However, since air and water have different physical properties, retests of some pipelines not meeting field air tests have been successful when tested with water. The leakage rates of 0.0017 CFM/ft2 and 0.0003 CFM/ft2, were determined empirically as the maximums for pipe to meet the 50 and 200 gal/(in. of internal diameter) (mile of sewer) (24h) test rates, respectively. 1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard. 1.6 This standard does not
purport to address all the safety concerns, if any, associated with
its use. It is the responsibility of the user of this standard to
establish the appropriate safety and health practices and to
determine the applicability of regulatory limitations prior to its
use.
|
|
Standard Terminology Relating to Concrete Pipe and Related Products
|
|
Standard Test Method for Concrete Pipe Sewerlines by Negative Air Pressure (Vacuum) Test Method
|
|
Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
|
|
Standard Practice for Testing Concrete Pipe Sewer Lines by Low-Pressure Air Test Method |
Historická
1.5.2009
Historická
1.5.2010
Historická
1.1.2013
Historická
1.5.2009
Historická
1.5.2010
Historická
1.5.2010
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 26.12.2024 (Počet položek: 2 217 217)
© Copyright 2024 NORMSERVIS s.r.o.