Standard Specification for Flexible, Low Permeance Vapor Retarders for Thermal Insulation
Automaticky přeložený název:
Standardní specifikace pro flexibilní, nízké prostupu Vapor zpomalovače pro zateplování
NORMA vydána dne 1.9.2012
Označení normy: ASTM C1136-12
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2012
Kód zboží: NS-9663
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
flexible, low permeance, thermal insulation, vapor retarders, ICS Number Code 91.100.60 (Thermal and sound insulating materials)
Significance and Use | ||||||||||||||||||||||||||
9.1 Entrapment of water in thermal insulation caused by condensation of water vapor that has penetrated into the insulation is detrimental to the thermal resistance of the insulation. For this reason, in certain installations where temperature and moisture conditions have the potential to create a vapor driving force toward the insulation, a deterrent to the passage of such vapor into the installed insulation needs to be provided. This is the primary function of the vapor retarder. 9.2 In addition to the function stated in 9.3 This specification is used to specify material by physical property requirements that address the above prerequisites. The designer of an insulation system, after determining the degree of protection needed for the insulation, can use this specification to specify the appropriate type of vapor retarder when one is required. |
||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||
1.1 This specification covers vapor retarders for thermal insulation, specifically, flexible materials with permeance of 0.10 perm or lower and surface burning characteristics of 25 flame spread/50 smoke or lower. These materials are intended for use at surface temperatures of −20 to 150°F (−29 to 66°C). It does not cover mastics or barrier coatings applied in liquid form, nor materials intended for use as weather barriers. 1.2 This is a material specification and does not imply that an installed system using these materials will provide the physical properties specified in Section 1.3 This specification provides physical requirements for vapor retarders. Practice C755 provides assistance in solving problems related to moisture vapor transmission through thermal insulation materials. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 The following precautionary caveat pertains to the test methods portion only, Section 10, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||