Standard Specification for Seamless Copper Water Tube (Metric)
Přeložit název
NORMA vydána dne 1.4.2020
Označení normy: ASTM B88M-20
Datum vydání normy: 1.4.2020
Kód zboží: NS-992295
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
This specification covers seamless copper alloy water tubes for general plumbing and similar applications in fluid conveyance. These water tubes made from UNS C10200, C12000, and C12200 copper alloys are commonly used with solder, flared, or compression-type fittings. The materials should be cold-drawn to size and the tubes finished by cold working and annealing to produce the required temper and surface finish. When tubes are furnished in coils, annealing is done after coiling, while those furnished in straight lengths should be in the drawn temper. The numerical values in this specification are not presented in inch-pound units, but rather, in metric or SI units only.
Keywords:
copper tube, seamless, UNS No. C10200, UNS No. C12000, UNS No. C12200, water tube,, ICS Number Code 23.040.15 (Non-ferrous metal pipes)
Significance and Use | ||||||||||||||||||||||||||||||||||||
16.1 For purposes of determining compliance with the specified limits for requirements of the properties listed in Table 8, an observed value or calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29. |
||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||
1.1 This specification covers seamless copper water tube suitable for general plumbing, similar applications for the conveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper water tube suitable for any particular application is determined by the internal or external fluid pressure, by the installation and service conditions, and by local requirements. Means of joining or bending are also factors that affect the selection of the type of tube to be used.Note 1: Annealed tube is suitable for use with flared or compression fittings, and with solder-type fittings, provided rounding and sizing of the tube ends is performed where needed. Note 2: Drawn temper tube is suitable for use with solder-type
fittings. Types A and B tube, in the drawn temper, are suitable for
use with certain types and sizes of compression
fittings.
1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:
1.3 The assembly of copper plumbing or fire sprinkler systems by soldering is described in Practice B828. 1.4 Solders for joining copper potable water or fire sprinkler systems are covered by Specification B32. The requirements for acceptable fluxes for these systems are covered by Specification B813. 1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. Note 3: This specification is the SI companion to
Specification B88.
1.6 The following safety hazards caveat pertains only to the test methods portion, Section 15, of this specification: 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||
|