Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Seamless Copper Water Tube
Přeložit název
NORMA vydána dne 1.10.2016
Označení normy: ASTM B88-16
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2016
Kód zboží: NS-668446
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
copper tube, seamless, water tube, UNS No. C12000, UNS No. C12200,, ICS Number Code 23.040.15 (Non-ferrous metal pipes)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||
17.1 For purposes of determining compliance with the specified limits for requirements of the properties listed in Table 7, an observed value or calculated value shall be rounded as indicated in accordance with the rounding method of Practice E29. |
||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||
1.1 This specification establishes the requirements for seamless copper water tube suitable for general plumbing, similar applications for the conveyance of fluids, and commonly used with solder, flared, or compression-type fittings. The type of copper water tube suitable for any particular application is determined by the internal or external fluid pressure, by the installation and service conditions, and by local requirements. Means of joining or bending are also factors which affect the selection of the type of tube to be used.2 Note 1: Annealed tube is suitable for use with flared or
compression fittings, and with solder-type fittings, provided
rounding and sizing of the tube ends is performed where
needed.
Note 2: Drawn temper tube is suitable for use with solder-type
fittings. Types K and L tube, in the drawn temper, are suitable for
use with certain types and sizes of compression
fittings.
Note 3: Fittings used for soldered or brazed connections in
plumbing systems are described in ASME B16.18 and ASME
B16.22.
1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified.
1.3 The assembly of copper plumbing or fire sprinkler systems by soldering is described in Practice B828. 1.4 Solders for joining copper potable water or fire sprinkler systems are covered by Specification B32. The requirements for acceptable fluxes for these systems are covered by Specification B813. 1.5 Units—This specification is the companion specification to SI Specification B88M; therefore, no SI equivalents are shown in this specification. 1.6 The following safety hazards caveat pertains only to the test methods portion, Section 16, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 02.05.2025 (Počet položek: 2 198 171)
© Copyright 2025 NORMSERVIS s.r.o.