ČSN EN IEC 60079-14-ed.5 (332320)

Výbušné atmosféry - Část 14: Návrh elektrické instalace, výběr a instalace zařízení, včetně výchozí prohlídky (Norma k přímému použití jako ČSN).

Přeložit název

NORMA vydána dne 1.7.2025


Jazyk
Provedení
DostupnostSKLADEM
Cena1159.00 bez DPH
1 159.00

Informace o normě:

Označení normy: ČSN EN IEC 60079-14-ed.5
Třídící znak: 332320
Katalogové číslo: 521870
Datum vydání normy: 1.7.2025
Kód zboží: NS-1224571
Přibližná hmotnost: 595 g (1.31 liber)
Země: Česká technická norma
Kategorie: Technické normy ČSN

Anotace textu normy ČSN EN IEC 60079-14-ed.5 (332320):

This part of IEC 60079 contains the specific requirements for the design of electrical systems, selection, installation and the required initial inspection of electrical installations of Ex Equipment in, or associated with, explosive atmospheres including requirements for documentation and personnel competency.

These requirements are in addition to the requirements for installations in non-hazardous areas.

NOTE 1 - For voltages up to 1 000 V AC or 1 500 V DC requirements of this document are based on installation requirements in the IEC 60364 series and for higher voltages in the IEC 61936 series, but other relevant national requirements can apply. For offshore, the IEC 61892 series is applicable.

NOTE 2 - Maximum voltages are limited by specific Types of Protection according to other parts of the IEC 60079 series and will be given in the documentation for the Ex Equipment.

This document applies to all electrical Ex Equipment including fixed, transportable, portable and personal, and installations, permanent or temporary.

NOTE 3 - Guidance on transportable, portable or personal equipment can be found in Annex I and IEC TS 60079 48.

This document does not apply to:

  • - electrical installations in mines susceptible to firedamp;

NOTE 4 - This document might apply to electrical installations in mines where explosive gas atmospheres other than firedamp can be formed and to electrical installations in the surface installation of mines.

- inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing);

- rooms used for medical purposes;

- electrical installations in areas where the hazard is due to flammable mist; and

- installation of non-electrical Ex Equipment (unless being part of an equipment assembly according IEC TS 60079-46).

NOTE 5 - Additional guidance on the requirements for hazards due to hybrid mixtures of dust or flyings and flammable gas or vapour is provided in Annex H.

NOTE 6 - The use of portable tools having an Ex Equipment certificate might introduce an ignition source which is beyond the scope of this document, for example: a drill which could create a high temperature at the work piece.

No account is taken in this document of the toxic hazards that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower flammable limit. In locations where personnel could be exposed to potentially toxic concentrations of flammable material, appropriate precautions are necessary. Such precautions are outside the scope of this document

Doporučujeme:

EviZak - všechny zákony včetně jejich evidence na jednom místě

Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !

Chcete vědět více informací? Podívejte se na tuto stránku.




Cookies Cookies

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů.