ČSN EN 1287 (137106)

Zdravotnětechnické armatury - Nízkotlaké termostatické směšovače - Obecné technické požadavky (Norma k přímému použití jako ČSN).

Přeložit název

NORMA vydána dne 1.9.2026


Jazyk
Provedení
DostupnostSKLADEM
Cena543.00 Kč bez DPH
543.00 Kč

Informace o normě:

Označení normy: ČSN EN 1287
Třídící znak: 137106
Katalogové číslo: 524243
Datum vydání normy: 1.9.2026
Kód zboží: NS-1282515
Počet stran: 60
Přibližná hmotnost: 180 g (0.40 liber)
Země: Česká technická norma
Kategorie: Technické normy ČSN

Anotace textu normy ČSN EN 1287 (137106):

This document specifies general construction, performance and material requirements for PN 10 thermostatic mixing valves (TMV) and includes test methods for the verification of mixed water temperature performance at the point of use below 45 °C. This does not exclude the selection of higher temperatures where available. When these devices are used to provide anti-scald protection for children, elderly and disabled persons the mixed water temperature shall be set at a suitable temperature (body temperature - 38 °C). In particular children are at risk to scalding at lower temperatures than adults. This does not obviate the need for supervision of young children.

It applies to valves intended for use on sanitary appliances in kitchens, washrooms (incl. all rooms with sanitary tapware, e.g. toilet and cloakrooms) and bathrooms operating under the conditions specified in Table 1.

This document allows TMVs to supply a single outlet or a small number of outlets in a "domestic" application (e.g. one valve, controlling a shower, bath, basin and/or, bidet), excluding valves specifically designed for supplying a large number of outlets (i.e. for institutional use).

The tests described are type tests (laboratory tests) and not quality control tests carried out during manufacture.

Table 1 - Conditions of use

Supply Operating rangea

limits recommended

Pressure

Static <= 1 MPa [<=10 bar]

Dynamic >= 0,01 MPa [>=0,1 bar] (0,02 to 0,1) MPa

[(0,2 to 1,0) bar]

Temperature

Hot <= 70 °C <= 65 °C

Cold <= 25 °C

NOTE -Low pressure thermostatic mixing valves are designed to provide sufficient mechanical strength for operation at 1 MPa (10 bar) static pressure.

a For low pressure thermostatic mixing valves complying with this table there are no acoustical requirements. Low pressure thermostatic mixing valves complying with this document can also be used with inlet supply pressures in the range from 0,1 MPa to 0,2 MPa (1,0 bar to 2,0 bar) on condition that acoustical performance is not a requirement of the installation

Doporučujeme:

Aktualizace technických norem

Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.

Chcete vědět více informací? Podívejte se na tuto stránku.




Cookies Cookies

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů.