ČSN EN 12341 (835612)

Kvalita ovzduší - Referenční gravimetrická metoda stanovení hmotnostní koncentrace frakcí aerosolových částic PM10 a PM2,5 (Norma k přímému použití jako ČSN).

Přeložit název

NORMA vydána dne 1.1.2024


Jazyk
Provedení
DostupnostSKLADEM
Cena567.00 bez DPH
567.00

Informace o normě:

Označení normy: ČSN EN 12341
Třídící znak: 835612
Katalogové číslo: 518188
Datum vydání normy: 1.1.2024
Kód zboží: NS-1161621
Počet stran: 64
Přibližná hmotnost: 192 g (0.42 liber)
Země: Česká technická norma
Kategorie: Technické normy ČSN

Kategorie - podobné normy:

Vnější ovzduší

Anotace textu normy ČSN EN 12341 (835612):

This document specifies a standard method for determining the PM10 or PM2,5 mass concentrations of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance. Measurements are performed with samplers with inlet designs as specified in Annex A, operating at a nominal flow rate of 2,3 m3/h, over a nominal sampling period of 24 h. The method covers the determination of ambient air concentrations of specific fractions of suspended particulate matter in zones classified as rural areas, urban-background areas, traffic-orientated locations and locations influenced by industrial sources. Measurement results are expressed in µg/m3, where the volume of air is the volume at ambient conditions near the inlet at the time of sampling. The range of application of this document is for 24 h measurements from approximately 1 µg/m3 (i.e. the limit of detection of the standard measurement method expressed as its uncertainty) up to 150 µg/m3 for PM10 and 120 µg/m3 for PM2,5. NOTE 1 - Although the European Standard is not validated for higher concentrations, its range of application could well be extended to ambient air concentrations up to circa 200 µg/m3 when using suitable filter materials (see 5.1.5.2). This document specifies procedures and gives requirements for the testing and use of so-called sequential samplers, equipped with a filter changer, suitable for extended stand-alone operation. Sequential samplers are commonly used throughout the European Union for the measurement of concentrations in ambient air of PM10 or PM2,5. However, this document does not exclude the use of single-filter samplers. NOTE 2 - Older versions of samplers, which conform to previous versions of EN 12341 [2 and 21], can still be used to evaluate equivalence of candidate methods, using the procedures described in EN 16450 [5] and in [11]. As newer versions of samplers tested under this document become available, discontinue the use of older reference samplers in EN 16450 and in [11]. Type testing reports of equivalent methods are still valid if they were commissioned prior to the availability of type approved reference samplers tested under this document. This document also provides guidance for the selection and testing of filters with the aim of reducing the measurement uncertainty of the results obtained when applying this document

Doporučujeme:

Aktualizace technických norem

Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.

Chcete vědět více informací? Podívejte se na tuto stránku.




Cookies Cookies

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.

Souhlas můžete odmítnout zde.

Zde máte možnost přizpůsobit si nastavení souborů cookies v souladu s vlastními preferencemi.

Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů.