Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Monitoring Atmospheric SO2 Deposition Rate for Atmospheric Corrosivity Evaluation
Přeložit název
NORMA vydána dne 1.5.2018
Označení normy: ASTM G91-11(2018)
Datum vydání normy: 1.5.2018
Kód zboží: NS-849483
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
atmospheric corrosion, exposures, lead peroxide cylinder, measurement, plate preparation, sulfate analysis, sulfation plates, sulfur dioxide,, ICS Number Code 13.040.20 (Ambient atmospheres)
Significance and Use | ||||||||||||||||
5.1 Atmospheric corrosion of metallic materials is a function of many weather and atmospheric variables. The effect of specific corrodants, such as sulfur dioxide, can accelerate the atmospheric corrosion of metals significantly. It is important to have information available for the level of atmospheric SO5.2 Volumetric analysis of atmospheric SO5.3 The sulfation plate method provides a simple technique to independently monitor the level of SO5.4 Sulfation plate or lead peroxide cylinder results may be used to characterize atmospheric corrosion test sites regarding the effective average level of SO5.5 Either sulfation plate or lead peroxide cylinder testing is useful in determining microclimate, seasonal, and long term variations in the effective average level of SO5.6 The results of these sulfur dioxide deposition rate tests may be used in correlations of atmospheric corrosion rates with atmospheric data to determine the sensitivity of the corrosion rate to SO2 level. 5.7 The sulfur dioxide monitoring methods may also be used with other methods, such as Practice G84 for measuring time of wetness and Test Method G140 for atmospheric chloride deposition, to characterize the atmosphere at sites where buildings or other construction is planned in order to determine the extent of protective measures required for metallic materials. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice covers two methods of monitoring atmospheric sulfur dioxide, SO2 deposition rates with specific application for estimating or evaluating atmospheric corrosivity as it applies to metals commonly used in buildings, structures, vehicles and devices used in outdoor locations. 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Chcete mít jistotu o platnosti užívaných předpisů?