Standard Practice for Preparing An Optical Microscope for Dimensional Measurements (Withdrawn 2003)
Automaticky přeložený název:
Standardní praxe pro přípravu optickým mikroskopem pro rozměrovou měření (Withdrawn 2003 )
NORMA vydána dne 26.6.1981
Označení normy: ASTM F728-81(2003)
Poznámka: NEPLATNÁ
Datum vydání normy: 26.6.1981
Kód zboží: NS-56271
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
bright-field, dark-field, dimensional, microscope, optical microscope, ICS Number Code 37.020 (Optical equipment)
1. Scope |
This standard was transferred to SEMI (www.semi.org) May 2003 1.1 This practice covers the preparation of an optical microscope for dimensional measurements. It is intended for preparing an optical microscope to measure the width of lines, in the range from 0.5 to 12 [mu]m, inclusive, on hard-surface photomasks and processed silicon wafers. 1.2 This practice is applicable for a microscope equipped with a micrometer attachment, such as an optical filar, video filar, optical image-shearing with optical or video display, optical image-scanning, or video image-scanning micrometer. Adjustment and calibration of the micrometer attachment is not included in this practice. 1.3 This practice is intended for observing optically transparent specimens in bright-field transmitted illumination or optically opaque specimens in bright-field reflected illumination. It is not intended for dark-field illumination. 1.4 This practice is limited to an optical microscope with an illumination system that is an integral part of the microscope body and includes a condenser lens. 1.5 No useful figure capable of showing the arrangement of components for all microscope designs is available; therefore, this practice does not contain illustrations and procedures which would suggest a specific microscope. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For more specific hazard statements, see Note 7, Note 8, and Note 17. |
Poslední aktualizace: 16.09.2025 (Počet položek: 2 234 278)
© Copyright 2025 NORMSERVIS s.r.o.