Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Evaluating the Quality of Molded Poly(Vinyl Chloride) (PVC) Plastic Pipe Fittings by the Heat Reversion Technique
Automaticky přeložený název:
Standardní zkušební metoda pro posuzování kvality lisovaných poly (vinylchloridu) (PVC), potrubní armatura z plastu, které Heat Reverze Technika
NORMA vydána dne 15.4.2010
Označení normy: ASTM F610/F610M-10
Poznámka: NEPLATNÁ
Datum vydání normy: 15.4.2010
Kód zboží: NS-55902
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
evaluating, fittings, plastic, PVC, quality, Heating tests--plastics, Heat reversion technique, Hydrostatic pressure test, Poly(vinyl chloride) (PVC) fittings, Quality assurance (QA), ICS Number Code 23.040.20 (Plastic pipes), 23.040.45 (Plastic fittings)
Significance and Use |
This test method is applicable to distinguish between properly and improperly molded PVC plastic pipe fittings. It can be used to: Determine whether cold slugs or unfused areas are present (Note 1), Determine the amount of molded-in stress produced by the molding process (Note 2), Reveal contamination, and Show the quality of the weld line. Note 1—A cold slug is a piece of material that enters the mold at a significantly lower temperature than the rest of the mass. Note 2—A stress-free part will generally have better properties and higher strength than those with a high degree of stress. Stress-free parts will generally react better when exposed to chemicals. |
1. Scope |
1.1 This test method covers a procedure for evaluating the quality of molded poly(vinyl chloride) (PVC) plastic pipe fittings after exposure to heat. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |