Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Using a 1.707-m [67.23-in.] Diameter Laboratory Test Roadwheel in Testing Tires
Automaticky přeložený název:
Běžná praxe pro použití 1,707-M [67.23-in.] Průměr laboratorní vyšetření Roadwheel při testování pneumatik
NORMA vydána dne 1.1.2016
Označení normy: ASTM F551/F551M-16
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2016
Kód zboží: NS-631202
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
durability, endurance, laboratory tire testing, structural fatigue, testing tires,, ICS Number Code 83.160.01 (Tyres in general)
Significance and Use | ||
5.1 The 1.707-m [67.23-in.] diameter laboratory test roadwheel is one of the most extensively employed testing devices for tire durability and endurance testing. 5.2 This test apparatus operating in the laboratory at controlled surface speeds, loads, and ambient temperatures simulates, to a degree, tire-operating conditions resembling actual service. Because of the roadwheel curvature, the test tire is fatigued more rapidly than a tire operating on a road. 5.3 The laboratory roadwheel described in this practice is suitable for comparative evaluation of tires under controlled operating and environmental conditions. 5.4 While the laboratory roadwheel may not reproduce structural fatigue exactly as it occurs in service, the laboratory wheel can be used to produce fatigue under controlled conditions. |
||
1. Scope | ||
1.1 This practice covers the requirements for a 1.707-m [67.23-in.] diameter laboratory roadwheel for durability and endurance testing of tires under controlled operating and environmental conditions. 1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see Section 7 and Note 1. |
||
2. Referenced Documents | ||
|
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 25.09.2024 (Počet položek: 2 350 354)
© Copyright 2024 NORMSERVIS s.r.o.