Test Method for Measuring Steady-State Primary Photocurrent [Metric] (Withdrawn 1999)
Automaticky přeložený název:
Zkušební metoda pro měření v ustáleném stavu Primární fotoproud [ Metric ] (Withdrawn 1999 )
NORMA vydána dne 1.1.1994
Označení normy: ASTM F448M-94
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.1994
Kód zboží: NS-55346
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Calorimeter, Current measurement-semiconductors, Electrical conductors-semiconductors, Insulated gate field-effect (semiconductor) devices, Irradiance/irradiation-semiconductors, Junction field-effect (semiconductor) devices, Radiation exposure-electronic components/devices, Thermoluminescent detector (TLD), Transistors, Zener diodes, steady-state primary photocurrents, test, ICS Number Code 31.260 (Optoelectronics. Laser equipment)
1. Scope |
1.1 This test method covers the measurement of steady-state primary photocurrent, pp , generated in semiconductor devices when these devices are exposed to ionizing radiation. These procedures are intended for the measurement of photocurrents greater than 10 -9 A[dot]s/Gy(Si or Ge), in cases for which the relaxation time of the device being measured is less than 25% of the pulse width of the ionizing source. The validity of these procedures for ionizing dose rates as great as 10 Gy(Si or Ge)/s has been established. The procedures may be used for measurements at dose rates as great as 10 10 Gy(Si or Ge)/s; however, extra care must be taken. Above 10 Gy/s the package response may dominate the device response for technologies such as complementary metal-oxide semiconductor, (CMOS)/silicon-on sapphire (SOS). Additional precautions are also required when measuring photocurrents of 10 -9 A[dot]s/Gy(Si or Ge) or lower. 1.2 Setup, calibration, and test circuit evaluation procedures are also included in the test method. 1.3 Procedures for lot qualification and sampling are not included in this test method. 1.4 Because of the variability between device types and in the requirements of different applications, the dose rate range over which any specific test is to be conducted is not given in the test method but must be specified separately. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |