Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Construction of Test Cell for Liquid Extraction of Flexible Barrier Materials
Automaticky přeložený název:
Standardní praxe pro stavebnictví zkušební komoře pro kapalina flexibilních bariérových materiálů
NORMA vydána dne 1.4.2013
Označení normy: ASTM F34-13
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2013
Kód zboží: NS-55013
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
extractables, flexible barrier materials, food simulating solvents, test cells, ICS Number Code 55.040 (Packaging materials and accessories)
Significance and Use | ||||||
5.1 Knowledge of extractives from flexible barrier materials may serve many useful purposes. A test cell constructed as described in this practice may be used for obtaining such data. Another test cell has been found equivalent to the one described in this practice. See the appendix for the source of the alternate cell. 5.2 United States Federal Regulations 21CFR 176.170 (d)(3), 21CFR 177.1330 (e)(4), 21CFR 177.1360 (b), 21CFR 177.1670 (b), and 21CFR Appendix VI (b) cite this standard practice as the basis for determining the amount of extractables from the surface of a package or multilayer film or modified paper in contact with food. In some cases, it is the only practice defined for this purpose. No alternative detail is given in the regulations for conducting extractions. 5.3 Test Method D4754 is not an equivalent to this test method. It is for two-sided extraction of films having the same material on both of the exposed surfaces of the film. |
||||||
1. Scope | ||||||
1.1 This practice covers the construction of test cells which may be used for the extraction of components from flexible barrier materials by suitable extracting liquids, including foods and food simulating solvents. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||
2. Referenced Documents | ||||||
|
Historická
1.2.2008
Historická
1.4.2008
Historická
1.10.2009
Historická
1.2.2009
Historická
1.8.2013
Historická
1.4.2011
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)