Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Analysis of Tin-Based Solder Alloys for Minor and Trace Elements Using Inductively Coupled Plasma Atomic Emission Spectrometry
Automaticky přeložený název:
Standardní zkušební metoda pro analýzu Tin - Based pájecí slitiny pro menší a stopové prvky Použití indukčně vázanou plazmou atomová emisní spektrometrie
NORMA vydána dne 1.5.2015
Označení normy: ASTM F3139-15
Poznámka: NEPLATNÁ
Datum vydání normy: 1.5.2015
Kód zboží: NS-611295
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
antimony, bismuth, cadmium, declarable substances, ICP-AES, inductively coupled plasma atomic emission spectrometry, lead, lead-free, mercury, RoHS, SAC, solder, tin solder,, ICS Number Code 25.220.40 (Metallic coatings)
Significance and Use | ||||||||||||||||||||||||||||||||||||||||||||||||||
4.1 Tin-based solder alloys are commonly used to manufacture electrical and electronic goods. The elements lead, cadmium, mercury, antimony and bismuth are often declarable substances in solder materials. This test method provides a means of determining the listed declarable substances, as well as other minor and trace constituents, in tin-based solder alloys. 4.2 Two methods of dissolving tin-based solder alloys are given in this standard. The first method uses open-vessel hydrofluoric and nitric acid room temperature digestions; the second method employs closed-vessel nitric and hydrofluoric acid microwave digestions, both for use only with ICP-AES instruments equipped with a hydrofluoric acid resistant sample introduction system. 4.3 The method of preparing calibration solutions uses 1000 mg/kg single element reference material solutions, and uses matching concentrated acids for both the calibration solutions and the sample solutions. 4.4 This test method is intended for use by laboratories experienced with the set-up, calibration and analysis of samples using ICP-AES. |
||||||||||||||||||||||||||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 This test method covers procedures for the analysis of tin-based solder alloys for minor and trace elements using inductively-coupled plasma atomic emission spectrometry (ICP-AES) instrumentation. 1.2 These test procedures were validated for the analytes and mass fractions listed below.
1.3 The procedures appear in the following order:
1.4 The values stated in SI units are to be regarded as the standard. Any other values are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||||||||||||||||||||||||
|
Poslední aktualizace: 14.01.2025 (Počet položek: 2 219 679)
© Copyright 2025 NORMSERVIS s.r.o.