Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Timed Evaluation of Forced-Entry-Resistant Systems
Automaticky přeložený název:
Standardní zkušební metoda pro Timed hodnocení nucené-entry-Resistant systémy
NORMA vydána dne 15.4.2014
Označení normy: ASTM F3038-14
Poznámka: NEPLATNÁ
Datum vydání normy: 15.4.2014
Kód zboží: NS-54885
Počet stran: 13
Přibližná hmotnost: 39 g (0.09 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
doors, forced-entry (FE), faç,ade, glass, glazing, impact, louvers, penetration resistance, security, systems, walls, windows, ICS Number Code 91.060.50 (Doors and windows)
Significance and Use | ||||||||||
5.1 Within a given period of time, the success or failure of any attempt to forcibly enter a structure intended to resist that entry is dependent upon three primary factors that collectively define the threat: (1) the tools and devices employed, (2) the number of aggressors, and (3) the level of sophistication of the attack. 5.2 The procedures presented herein are based on field experience and are not intended to be used to establish or confirm the absolute prevention of forced entries. 5.3 The test requirements specified herein have been established for use in evaluating the forced-entry resistance characteristics of structures and assemblies to be used in commercial, government, and military installations. 5.4 The procedures of this test method are intended to evaluate the time necessary for personnel to create an opening of sufficient size to permit passage of a test shape through it. |
||||||||||
1. Scope | ||||||||||
1.1 This test method sets forth the requirements and testing procedures to test forced-entry-resistant building components, construction components, and specialty security equipment. This test method is intended primarily for manufacturers to test and rate their windows, doors, modular panels, glazings, louvers, walls, seismic joints, roofs, roof hatches, grilles, and similar products to ensure that all manufactured products meet the necessary requirements for forced-entry protection. 1.2 This test method is currently designed to simulate a spontaneous mob using readily available hand tools as the primary threat for forced entry. 1.3 In order to receive a rating, all portions of the tested specimen must meet or exceed the test level. 1.4 Systems are required to be tested as complete units in a test frame or fielded conditions. Mulled systems must be tested in the mulled condition. Test results only apply to the component or system as tested. Once a system is tested and deemed to satisfy the requirements of this test method, no design change can be made without a retest. 1.5 Units—The values stated in this standard are SI units with the exception of the nominal descriptors for tools. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|
Historická
1.6.2014
Historická
1.1.2014
Historická
1.2.2009
Historická
1.4.2012
Historická
1.4.2008
Historická
1.2.2009
Chcete mít jistotu o platnosti užívaných předpisů?
Nabízíme Vám řešení, abyste mohli používat stále platné (aktuální) legislativní předpisy.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 01.11.2024 (Počet položek: 2 208 817)
© Copyright 2024 NORMSERVIS s.r.o.