Standard Specification for Ultra-High Molecular Weight Polyethylene Powder Blended With Alpha-Tocopherol (Vitamin E) and Fabricated Forms for Surgical Implant Applications
Automaticky přeložený název:
Standardní specifikace pro Ultra -High polyethylen Prášek mísí s alfa-tokoferol ( vitamin E) a kovodělných Formy pro chirurgický implantát Applications
NORMA vydána dne 1.12.2007
Označení normy: ASTM F2695-07
Poznámka: NEPLATNÁ
Datum vydání normy: 1.12.2007
Kód zboží: NS-54388
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
alpha-tocopherol, fabricated forms, powdered form, ultra-high molecular weight polyethylene, vitamin E, ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)
1. Scope | ||||||||||||||||||||||||||||
1.1 This specification covers ultra-high molecular weight polyethylene (UHMWPE) powder blended with alpha-tocopherol (vitamin E) intended for use in surgical implants. 1.2 The requirements of this specification apply to alpha-tocopherol-containing UHMWPE in two forms. One is virgin polymer powder blended with alpha-tocopherol prior to consolidation (Section 4). The second is any form fabricated from this blended, alpha-tocopherol-containing powder from which a finished product is subsequently produced (Section 5). This specification does not apply to finished or semi-finished products that are doped with vitamin E after consolidation. 1.3 Aside from blending with alpha-tocopherol, the provisions of Specifications F 648 and D 4020 apply. Special requirements detailed in this specification are added to describe powders containing alpha-tocopherol that will be used in surgical implants. This specification addresses material characteristics and does not apply to the packaged and sterilized finished implant. This specification also does not apply to UHMWPE materials extensively crosslinked by gamma and electron beam sources of ionizing radiation. 1.4 The following precautionary caveat pertains only to the fabricated forms portion, Section 5, of this specification. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||||
|