Standard Practice for The Sectional Repair of Damaged Pipe By Means of An Inverted Cured-In-Place Liner
Přeložit název
NORMA vydána dne 1.4.2016
Označení normy: ASTM F2599-16
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2016
Kód zboží: NS-637800
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
ambient cure, bladder, compression gasket, continuous, felt, hydrophilic O-ring, inflation, inversion, knit, launcher, liner/bladder assembly, resin, sectional cured-in-place lining, steam cure, textile, tube, vacuum impregnate,, ICS Number Code 23.040.99 (Other pipeline components)
Significance and Use | ||||||||||||||
4.1 This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations who are involved in the rehabilitation of pipes through the use of a resin-impregnated tube installed within a damaged existing host pipe. As for any practice, modifications may be required for specific job conditions. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice covers requirements and test methods for the sectional cured-in-place lining (SCIPL) repair of a pipe line (4 in. through 60 in. (10.2 cm through 152 cm)) by the installation of a continuous resin-impregnated-textile tube into an existing host pipe by means of air or water inversion and inflation. The tube is pressed against the host pipe by air or water pressure and held in place until the thermoset resins have cured. When cured, the sectional liner shall extend over a predetermined length of the host pipe as a continuous, one piece, tight fitting, corrosion resistant, and verifiable non-leaking cured-in-place pipe. 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 There is no similar or equivalent ISO Standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 11.09.2024 (Počet položek: 2 346 290)
© Copyright 2024 NORMSERVIS s.r.o.