Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Measurement of Magnetically Induced Torque on Passive Implants in the Magnetic Resonance Environment
Automaticky přeložený název:
Standardní zkušební metoda pro měření magnetického indukčního momentu na pasivním Implantáty v magnetické rezonance pro životní prostředí
NORMA vydána dne 1.1.2004
Označení normy: ASTM F2213-04
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2004
Kód zboží: NS-53215
Počet stran: 7
Přibližná hmotnost: 21 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
force, magnetic, implant, metals (for surgical implants), MRI (magnetic resonance imaging), MR safety, torque, magnetic, ICS Number Code 17.220.20 (Measurement of electrical and magnetic quantities)
1. Scope | ||||||||||
1.1 This test method covers the measurement of the magnetically induced torque produced by the static magnetic field in the magnetic resonance environment on medical devices and the comparison of that torque to the equivalent torque applied by the gravitational force to the implant. 1.2 This test method does not address other possible safety issues which include but are not limited to issues of magnetically induced force due to spatial gradients in the static magnetic field, RF heating, induced heating, acoustic noise, interaction among devices, and the functionality of the device and the MR system. 1.3 The torque considered here is the magneto-static torque due to the interaction of the MRI static magnetic field with the magnetization in the implant. The dynamic torque due to interaction of the static field with eddy currents induced in a rotating device is not addressed in this test method. Currents in lead wires may induce a torque as well. 1.4 The sensitivity of the torque measurement apparatus must be greater than 1/10 the "gravity torque," the product of the device's maximum linear dimension and its weight. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||
2. Referenced Documents | ||||||||||
|