Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determining the Effect of Variable Frequency Vibration on a Membrane Switch or Membrane Switch Assembly
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení účinku proměnnou frekvencí vibrací na fóliovou nebo montáž membránových tlačítek
NORMA vydána dne 1.2.2011
Označení normy: ASTM F2188-02(2011)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.2.2011
Kód zboží: NS-53119
Počet stran: 2
Přibližná hmotnost: 6 g (0.01 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
contact closure, frequency, membrane switch, vibration, Cable interconnect, Contact closure, Electronic mounting hardware, Frequency membrane switch, Membrane switches, Random variables/variation, Random vibration test, Ribbon interconnect, Sinusoidal motion/vibration, Switch contacts, Vibration test, ICS Number Code 29.120.40 (Switches)
Significance and Use |
Vibration encountered in the field is not usually simple harmonic. This test can be used to determine relative motion between parts, critical frequencies, adhesion strengths, loosening of parts or other physical effects that can cause fatigue or failure. Experience has shown that this test will expose potential failures associated with the electronic components of a membrane switch, where tests of lower levels will not. This practice can be used to qualify a membrane switch for aerospace, medical and other applications. This test is potentially destructive, intended for device qualification. Either Test Condition A or B can be chosen, based upon the intent of the test determined by the qualified engineer. |
1. Scope |
1.1 This test method establishes procedures for determining the effect of sinusoidal vibration, within the specified frequency range, on switch contacts, mounting hardware, adhered component parts, solder or heat stakes, tactile devices, and cable or ribbon interconnects associated with a membrane switch or membrane switch assembly. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |