Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Testing the Biological Responses to Particles In Vivo
Automaticky přeložený název:
Standardní postup zkoušení biologické Odpovědi na částice in vivo
NORMA vydána dne 1.11.2003
Označení normy: ASTM F1904-98(2003)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2003
Kód zboží: NS-52033
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
biocompatibility, biological response, in vivo, interleukins, particles, ICS Number Code 11.040.40 (Implants for surgery, prothetics and orthotics)
Significance and Use | ||||||||
This practice is to be used to help assess the biocompatibility of materials used in medical devices. It is designed to test the effect of particles from the materials on the host tissues. The appropriateness of the methods should be carefully considered by the user since not all materials or applications need be tested by this practice. The validity of these studies in predicting the human response is not known at this time and studies such as described here are needed. Abbreviation Used: 4.3.1 LPS—Lipopolysaccharide (endotoxin). 4.3.2 LAL—Limulus amebocyte lysate. 4.3.3 PCR—Polymerase chain reaction. 4.3.4 CD—Cluster differentiation. 4.3.5 HLA—Human leukocyte antigens. |
||||||||
1. Scope | ||||||||
1.1 This practice covers the production of wear debris and degradation products from implanted materials that may lead to a cascade of biological responses resulting in damage to adjacent and remove tissues. In order to ascertain the role of particles in stimulating such responses, the nature of the responses, and the consequences of the responses, established protocols are needed. This is an emerging, rapidly developing area and the information gained from standard protocols is necessary to interpret responses. Some of the procedures listed here may, on further testing, not prove to be predictive of clinical responses to particulate debris. However, only the use of standard protocols will establish which are useful techniques. Since there are many possible and established ways of determining responses, a single standard protocol is not stated. However, this recommended practice indicates which necessary information should be supplied with the test results. For laboratories without established protocols, recommendations are given and indicated with an asterisk. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||
2. Referenced Documents | ||||||||
|