Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits
Automaticky přeložený název:
Standardní postup instalace z poly ( vinylchloridu ) ( PVC) profilového pásu Liner a cementová zálivka pro rehabilitaci existujících Man - Entry kanalizací a potrubí
NORMA vydána dne 10.9.2002
Označení normy: ASTM F1698-02
Poznámka: NEPLATNÁ
Datum vydání normy: 10.9.2002
Kód zboží: NS-51210
Počet stran: 6
Přibližná hmotnost: 18 g (0.04 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
PVC, conduits, installation, verticle, grout, fabrication, liner, ICS Number Code 23.040.20 (Plastic pipes), 83.080.20 (Thermoplastic materials)
Significance and Use | ||||||||||||||
This practice is for use by designers and specifiers, regulatory agencies, owners, and inspection organizations involved in the rehabilitation of non-pressure sewers and conduits. As for any practice, modifications may be required for specific job conditions. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This practice describes the procedures for the rehabilitation of sewer lines and conduits by the installation of a field-fabricated PVC liner. After installation of the liner, cementitious grout is injected into the annular space between the liner and the existing sewer or conduit. The rehabilitation of the host structure by this installation practice results in a rigid composite structure (PVC/grout/existing pipe). This rehabilitation process may be used in a variety of gravity applications, such as sanitary sewers, storm sewers and process piping of man-entry sizes (36 to 144 in. in vertical dimension). The profile strips used for field fabrication of PVC liners are supplied in coils for spiral winding of the liner or in custom-cut flat panels for circumferential lining of all or any portion of the circumference of the host conduit (see Figs.1 and 2). 1.2 The values in parentheses are provided for information purposes only. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Particular attention is drawn to those safety regulations and requirements involving entering into and working in confined spaces. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete pravidelně odebírat informace o nově vycházejících normách z celého světa a to zcela zdarma?
Přihlašte se k odběru. Vše je velice jednoduché a absolutně ZDARMA.
Na výběr máte vydavatele z celého světa.
Poslední aktualizace: 06.07.2025 (Počet položek: 2 207 474)
© Copyright 2025 NORMSERVIS s.r.o.