Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
Automaticky přeložený název:
Standardní specifikace pro skládané poly (vinyl chloridu ) ( PVC) trubky pro stávající kanalizace a Conduit rehabilitace
NORMA vydána dne 15.11.2010
Označení normy: ASTM F1504-10
Poznámka: NEPLATNÁ
Datum vydání normy: 15.11.2010
Kód zboží: NS-50542
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
installationunderground, plastic pipethermoplastic, poly(vinyl chloride) (PVC) plastic pipe, rehabilitation, Conduits--specifications, Folded PVC pipe, Nonpressure piping--specifications, Poly(vinyl chloride)(PVC) pipe--specifications, Rehabilitation--sewerlines, Sewer pipe (thermoplastic)--specifications, Thermoplastic pipe/tube/fittings--specifications, Underground installation--water supply/distribution systems, ICS Number Code 23.040.20 (Plastic pipes), 83.080.20 (Thermoplastic materials)
1. Scope | ||||||||||||||||||||||||
1.1 This specification covers requirements and test methods for materials, dimensions, workmanship, flattening resistance, impact resistance, pipe stiffness, extrusion quality, and a form of marking for folded (vinyl chloride) (PVC) pipe for existing sewer and conduit rehabilitation. 1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabilitation where the folded PVC pipe is inserted into and then expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. Note 1—For installation procedures refer to Practice F1947. 1.3 This specification includes pipe made only from materials specified in Section 6. This specification does not include pipe manufactured from reprocessed, recycled, or reclaimed PVC. 1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.5 The following precautionary statement pertains to the test method portion only, Section 11, of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||
|
Poslední aktualizace: 20.10.2025 (Počet položek: 2 239 217)
© Copyright 2025 NORMSERVIS s.r.o.