Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Verifying the Alignment of X-Ray Diffraction Instrumentation for Residual Stress Measurement
Automaticky přeložený název:
Standardní zkušební metoda pro Ověření vyrovnání rentgenové difrakce Instrumentation pro vnitřní pnutí měření
NORMA vydána dne 1.1.1996
Označení normy: ASTM E915-96
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.1996
Kód zboží: NS-48460
Počet stran: 3
Přibližná hmotnost: 9 g (0.02 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Alignment, Instrumental measurement,emcorrosion, Iron,empowder, Metals and metallic materials, Misalignment, Precision,eminstrumentation, Residual stress, Stress,emmetallic materials, Structural analysis/applications, Verification, X-ray diffraction, verifying alignment of X-ray diffraction instrumentation (for residual, stress measurement)
1. Scope | ||
1.1 This test method covers the preparation and use of a flat stress-free test specimen for the purpose of checking the systematic error caused by instrument misalignment or sample positioning in X-ray diffraction residual stress measurement, or both. 1.2 This test method is applicable to apparatus intended for X-ray diffraction macroscopic residual stress measurement in polycrystalline samples employing measurement of a diffraction peak position in the high-back reflection region, and in which the [theta], 2[theta], and [psi] rotation axes can be made to coincide (see Fig. 1). 1.3 This test method describes the use of iron powder which has been investigated in round-robin studies for the purpose of verifying the alignment of instrumentation intended for stress measurement in ferritic or martensitic steels. To verify instrument alignment prior to stress measurement in other alloys, base metal powder having the same crystal structure as the alloy should be prepared in similar fashion and used to check instrument alignment at the appropriate diffraction angle. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||
2. Referenced Documents | ||
|
Poslední aktualizace: 17.05.2024 (Počet položek: 2 902 148)