Standard Guide for Sensor Set Design and Irradiation for Reactor Surveillance, E 706(IIC)
Automaticky přeložený název:
Standardní Průvodce pro Sensor Scéna a ozařováním reaktorů Surveillance , E 706 ( IIC )
NORMA vydána dne 10.2.2003
Označení normy: ASTM E844-03
Poznámka: NEPLATNÁ
Datum vydání normy: 10.2.2003
Kód zboží: NS-48244
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
activity, dosimeter, fission monitor, monitor, monitor foil, neutron fluence, pressure vessel, radiometric monitor, reaction rate, reactor surveillance, sensor, ICS Number Code 17.240 (Radiation measurements)
Significance and Use | ||||||||||||||||||
In neutron dosimetry, a fission or non-fission dosimeter, or combination of dosimeters, can be used for determining a fluence-rate, fluence, or neutron spectrum, or both, in nuclear reactors. Each dosimeter is sensitive to a specific energy range, and, if desired, increased accuracy in a flux-spectrum can be achieved by the use of several dosimeters each covering specific neutron energy ranges. A wide variety of detector materials is used for various purposes. Many of these substances overlap in the energy of the neutrons which they will detect, but many different materials are used for a variety of reasons. These reasons include available analysis equipment, different cross sections for different flux levels and spectra, preferred chemical or physical properties, and, in the case of radiometric dosimeters, varying requirements for different half-life isotopes, possible interfering activities, and chemical separation requirements. |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This guide covers the selection, design, irradiation, post-irradiation handling, and quality control of neutron dosimeters (sensors), thermal neutron shields, and capsules for reactor surveillance neutron dosimetry. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in parentheses are for information only. 1.3 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 11.07.2025 (Počet položek: 2 208 012)
© Copyright 2025 NORMSERVIS s.r.o.