Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Testing Homogeneity of Materials for Development of Reference Materials (Withdrawn 2005) (Includes all amendments And changes 12/31/2010).
Automaticky přeložený název:
Standardní postup zkoušení homogenity Materiály pro rozvoj referenční materiály (Withdrawn 2005 )
NORMA vydána dne 1.1.1996
Označení normy: ASTM E826-85(1996)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.1996
Kód zboží: NS-48139
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Homogeneity, Instrumental measurement,emspectrochemical, Metals and metallic materials, Optical emission spectrometric (OES) analysis, Reference samples/specimens, Spectral data, Spectrochemical analysis, Spectroscopy,ememission, Spectroscopy,emflame emission, Spectroscopy,emX-ray emission, X-ray emission spectrometry, homogeneity of metals (solid/powdered)/finely ground oxides (intended, for use as reference materials in X-ray emission/optical emission, spectroscopy), practice,,Order Form
1. Scope | ||||||||||||||||||
1.1 This practice is suitable for testing the homogeneity of metals, either in solid or powdered form, and finely ground oxide materials that are intended for use as reference materials in X-ray emission, or optical emission spectroscopy, or both. The criteria for acceptance of the test specimens as reference materials, however, must be previously determined by the user for meeting his specific requirements. 1.2 The procedure is designed primarily for testing specimens by X-ray emission spectrometry or optical emission spectroscopy, or both. However, the practice could be easily adapted for use with other instrumental techniques such as atomic absorption spectrophotometry. 1.3 This procedure can be applied to one or more elements in a specimen provided the signal-to-background ratio is not a limiting factor. 1.4 This practice includes one method, if desired, to correct for systematic or periodic (sinusoidal) drift in the instrument with time through the use of a control reference material. Note 1-Caution: If serious drift occurs (for example, unstable power supply, X-ray tube, etc.) erroneous conclusions may be obtained from the data analysis.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 18.07.2025 (Počet položek: 2 208 817)
© Copyright 2025 NORMSERVIS s.r.o.