Standard Test Method for Effect of Impact on Bonding of Sprayed Fire-Resistive Material Applied to Structural Members
Automaticky přeložený název:
Standardní zkušební metoda pro Vliv Dopad na lepení stříkaného Fire-odporového materiálu aplikovaného na konstrukční prvky
NORMA vydána dne 1.4.2011
Označení normy: ASTM E760-92(2011)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.4.2011
Kód zboží: NS-47916
Počet stran: 2
Přibližná hmotnost: 6 g (0.01 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
impact loading, sprayed fire-resistive material, steel floor deck: Bond strength--building materials, Fire-resistant materials/testing, Impact testing, Loading tests--building constructions/materials, Sprayed fire-resistive materials (SFRMs), Steel deck, ICS Number Code 13.220.50 (Fire-resistance of building materials and elements)
Significance and Use | ||||||||
The intent of this test method is to determine a property of SFRM that may be used to provide an indication of its in-place serviceability. Satisfactory performance of SFRM applied to structural members and assemblies depends upon its ability to withstand the various influences that may occur during construction and during the life of the structure, as well as upon its satisfactory performance under fire conditions. The test method measures the behavior of SFRM when the floor construction to which it is applied is subjected to shock loading and evaluates adhesion and resistance to spalling, cracking, and delamination. It is an indication of the ability of SFRM to remain in place and resist removal during anticipated service conditions. |
||||||||
1. Scope | ||||||||
1.1 This test method covers a procedure for determining the effect of impact loading on the bonding of sprayed fire-resistive material (SFRM) applied to the underside of steel floor deck. These materials include sprayed fibrous and cementitious materials applied directly in contact with the structural members. The test method is applicable only to laboratory procedures. 1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||