Standard Test Method for Arrhenius Kinetic Constants for Thermally Unstable Materials Using Differential Scanning Calorimetry and the Flynn/Wall/Ozawa Method
Automaticky přeložený název:
Standardní zkušební metoda pro Arrhenius Kinetic konstanty pro teplotně nestálá materiálů pomocí diferenční skenovací kalorimetrie a Flynn / zdi / Ozawa metody
NORMA vydána dne 1.3.2011
Označení normy: ASTM E698-11
Poznámka: NEPLATNÁ
Datum vydání normy: 1.3.2011
Kód zboží: NS-47703
Počet stran: 8
Přibližná hmotnost: 24 g (0.05 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Arrhenius kinetic parameters, differential scanning calorimetry, hazard potential, kinetics, thermal analysis, thermal hazard, thermal stability, Arrhenius kinetic constants, Thermal stability, Differential scanning calorimetry (DSC), Thermal analysis (TA), ICS Number Code 19.040 (Environmental testing)
Significance and Use | ||||||||||||||||||
The Arrhenius parameters combined with the general rate law and the reaction enthalpy can be used for the determination of thermal explosion hazards (1) |
||||||||||||||||||
1. Scope | ||||||||||||||||||
1.1 This test method covers the determination of the overall kinetic parameters for exothermic reactions using the Flynn/Wall/Ozawa method and differential scanning calorimetry. 1.2 This technique is applicable to reactions whose behavior can be described by the Arrhenius equation and the general rate law. 1.3 Limitations—There are cases where this technique is not applicable. Limitations may be indicated by curves departing from a straight line (see 11.2) or the isothermal aging test not closely agreeing with the results predicted by the calculated kinetic values. In particular, this test method is not applicable to reactions that are partially inhibited. The technique may not work with reactions that include simultaneous or consecutive reaction steps. This test method may not apply to materials that undergo phase transitions if the reaction rate is significant at the transition temperature. 1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.5 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||
|
Historická
1.4.2012
Historická
1.11.2013
Historická
1.11.2012
Historická
1.2.2013
Historická
1.4.2012
Historická
1.6.2013
Poskytování aktuálních informací o legislativních předpisech vyhlášených ve Sbírce zákonů od roku 1945.
Aktualizace 2x v měsíci !
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.