Standard Test Methods for Chemical Analysis of Carbon Steel, Low-Alloy Steel, Silicon Electrical Steel, Ingot Iron, and Wrought Iron (Includes all amendments And changes 8/16/2017).
Automaticky přeložený název:
Standardní zkušební metody pro chemickou analýzu uhlíkové oceli, nízkolegované , křemíkové elektrooceli , ingotové železa , a tepaného železa
NORMA vydána dne 1.1.2000
Označení normy: ASTM E350-95(2000)e1
Poznámka: NEPLATNÁ
Datum vydání normy: 1.1.2000
Kód zboží: NS-46519
Počet stran: 58
Přibližná hmotnost: 174 g (0.38 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
aluminum, antimony, bismuth, boron, calcium, carbon steel, cerium, chromium, cobalt, copper, ingot iron, lead, low-alloy steel, manganese, molybdenum, nickel, phosphorus, silicon, silicon electrical steel, tin, titanium, vanadium, ICS Number Code 77.040.30 (Chemical analysis of metals)
1. Scope | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.1 These test methods cover the chemical analysis of carbon steels, low-alloy steels, silicon electrical steels, ingot iron, and wrought iron having chemical compositions within the following limits:
1.2 The test methods in this standard are contained in the sections indicated as follows:
1.3 Test methods for the determination of several elements not included in this standard can be found in Test Methods E30 and Test Methods E1019. 1.4 Some of the concentration ranges given in 1.1 are too broad to be covered by a single test method and therefore this standard contains multiple test methods for some elements. The user must select the proper test method by matching the information given in the Scope and Interference sections of each test method with the composition of the alloy to be analyzed. 1.5 The values stated in SI units are to be regarded as standard. In some cases, exceptions allowed in Practice E380 are also used. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 5 and in special "Warning" paragraphs throughout these test methods. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2. Referenced Documents | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|