Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Practice for Probability of Detection Analysis for â Versus a Data
Automaticky přeložený název:
Standardní praktiky pro Pravděpodobnost analýzu detekce & # XE2 ; Versus datového
NORMA vydána dne 15.6.2015
Označení normy: ASTM E3023-15
Poznámka: NEPLATNÁ
Datum vydání normy: 15.6.2015
Kód zboží: NS-612515
Počet stran: 12
Přibližná hmotnost: 36 g (0.08 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
a-hat vs. a, ahat vs. a, eddy current inspection, eddy current POD, Linear Regression, POD, POD analysis, probability of detection, regression,, ICS Number Code 19.100 (Non-destructive testing)
Significance and Use | ||||||||||||||||
5.1 The POD analysis method described herein is based on well-known and well-established statistical methods. It shall be used to quantify the demonstrated POD for a specific set of examination parameters and known range of discontinuity sizes under the following conditions. 5.1.1 The initial response from a nondestructive evaluation inspection system is measurable and can be classified as a continuous variable. 5.1.2 The relationship between discontinuity size (a) and measured signal response (5.2 This practice does not limit the use of other statistical models if justified as more appropriate for the 5.3 This practice is not appropriate for data resulting from a POD examination on nondestructive evaluation systems that generate an initial response that is binary in nature (for example, hit/miss). Practice E2862 is appropriate for systems that generate a hit/miss-type response (for example, fluorescent penetrant). 5.4 Prior to performing the analysis it is assumed that the discontinuity of interest is clearly defined; the number and distribution of induced discontinuity sizes in the POD specimen set is known and well documented; the POD examination administration procedure (including data collection method) is well designed, well defined, under control, and unbiased; the initial inspection system response is measurable and continuous in nature; the inspection system is calibrated; and the measurement error has been evaluated and deemed acceptable. The analysis results are only valid if the 5.5 The POD analysis method described herein is consistent with the analysis method for â versus a data described in MIL-HDBK-1823A and is included in several widely utilized POD software packages to perform a POD analysis on â versus a data. It is also found in statistical software packages that have linear regression capability. This practice requires that the analyst has access to either POD software or other software with linear regression capability. |
||||||||||||||||
1. Scope | ||||||||||||||||
1.1 This practice defines the procedure for performing a statistical analysis on Nondestructive Testing (NDT) 1.2 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||
2. Referenced Documents | ||||||||||||||||
|
Poslední aktualizace: 30.04.2024 (Počet položek: 2 896 468)
© Copyright 2024 NORMSERVIS s.r.o.