Standard Test Method for Determination of Thiodiglycol on Wipes by Solvent Extraction Followed by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
Přeložit název
NORMA vydána dne 1.5.2021
Označení normy: ASTM E2838-21
Datum vydání normy: 1.5.2021
Kód zboží: NS-1024074
Počet stran: 10
Přibližná hmotnost: 30 g (0.07 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
chemical warfare agent, liquid chromatography, mass spectrometry, pressurized fluid extraction, single reaction monitoring, sonication, thiodiglycol, wipe,, ICS Number Code 97.080 (Cleaning appliances)
Significance and Use | ||||||||||||||
5.1?This is a performance-based method, and modifications are allowed to improve performance. 5.1.1?Due to the rapid development of newer instrumentation and column chemistries, changes to the analysis described in this standard are allowed as long as better or equivalent performance data result. Any modifications shall be documented and performance data generated. The user of the data generated by this standard shall be made aware of these changes and given the performance data demonstrating better or equivalent performance. 5.2?TDG is a Schedule 2 compound under the Chemical Weapons Convention (CWC).5.3?This method has been investigated for use on surface wipes. TDG is also a human metabolite resulting from sulfur mustard exposure but this method has not been investigated for such determinations. |
||||||||||||||
1. Scope | ||||||||||||||
1.1?This procedure details the determination of thiodiglycol (TDG), also known as 2,2-thiobis-ethanol, on wipes with 3,3-thiodipropanol (TDP) as the surrogate. This method is based upon solvent extraction of wipes by either sonication or a pressurized fluid extraction (PFE) technique as an alternative option. The extract is filtered, concentrated, and analyzed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). TDG is qualitatively and quantitatively determined. 1.2?UnitsThe values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3?The method detection limit (MDL)2 and reporting range1.4?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.5?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 02.05.2025 (Počet položek: 2 198 171)
© Copyright 2025 NORMSERVIS s.r.o.