Standard Test Methods for Evaluating Water-Resistive Barrier (WRB) Coatings Used under Exterior Insulation and Finish Systems (EIFS) or EIFS with Drainage
Automaticky přeložený název:
Standardní zkušební metody pro hodnocení Water - odporová závora ( WRB ) povlaky používány pod vnější izolace a dokončit systémy ( EIF ) nebo EIFS s odvodněním
NORMA vydána dne 1.9.2007
Označení normy: ASTM E2570-07
Poznámka: NEPLATNÁ
Datum vydání normy: 1.9.2007
Kód zboží: NS-45626
Počet stran: 5
Přibližná hmotnost: 15 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
coating, drainage, Exterior Insulation and Finish System (EIFS), substrate, Water Resistive Barrier (WRB), ICS Number Code 91.060.10 (Walls. Partitions. Facades)
Significance and Use | ||||||||||||||||||||||||||
This series of test methods provides a means to evaluate performance of the water-resistive barrier coating when subjected to various physical and environmental conditions. The water-resistive barrier coating is applied between the EIFS and substrate in an EIFS-clad wall assembly and is intended to provide additional protection to the building and its contents from incidental moisture intrusion that may occur through the building envelope. Although protected from direct weather exposure after the EIFS is installed, the coating must be durable and weather resistant as it is subjected to various environmental conditions prior to application of the EIFS as well as while the system is in service. |
||||||||||||||||||||||||||
1. Scope | ||||||||||||||||||||||||||
1.1 These test methods apply to trowel, roller, or spray applied Water-resistive barrier (WRB) coatings that are applied over exterior sheathing prior to application of EIFS or EIFS with drainage wall claddings. 1.2 Test methods for in place wall system and cladding related to tests such as fire resistance, wind load capability, air barrier performance, and so forth. should also be considered but are outside the scope of this document. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||||||||
2. Referenced Documents | ||||||||||||||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 22.12.2024 (Počet položek: 2 217 000)
© Copyright 2024 NORMSERVIS s.r.o.