Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Guide to Scanner and Tip Related Artifacts in Scanning Tunneling Microscopy and Atomic Force Microscopy
Automaticky přeložený název:
Standardní Průvodce po Scanner a Tip Související Artefakty v Scanning Tunneling mikroskopie a mikroskopie atomárních sil
NORMA vydána dne 1.11.2012
Označení normy: ASTM E2382-04(2012)
Poznámka: NEPLATNÁ
Datum vydání normy: 1.11.2012
Kód zboží: NS-45189
Počet stran: 18
Přibližná hmotnost: 54 g (0.12 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
Abbe offset error, creep, dilation, hysteresis, nonlinearity, probe-sample mixing, AFM, STM, tip shape, proximal probe, geometric mixing, image reconstruction, ICS Number Code 17.040.20 (Properties of surfaces)
Significance and Use | ||
4.1 This compilation is limited to artifacts observed in scanning tunneling microscopes and contact-mode atomic force microscopes. In particular, this document focuses on artifacts related to probe motion and geometrical considerations of the tip and surface interaction. Many of the artifacts described here extend to other scanned probe microscopies where piezoscanners are used as positioning elements or where tips of similar geometries are used. These are not the only artifacts associated with measurements obtained by STM or AFM. Artifacts can also arise from the following: control electronics (for example, improper feedback gains); noise (mechanical, acoustic, or electronic); drift (thermal or mechanical); problems unique to signal detection methods (for example, laser spillover in optical lever schemes); improper use of image processing (real time or post processed); sample preparation, environment (for example, humidity) and tip-surface interaction (for example, excessive electrostatic, adhesive, shear, and compressive forces). It is suggested that these other types of artifacts form the basis of future ASTM guides. |
||
1. Scope | ||
1.1 All microscopes are subject to artifacts. The purpose of this document is to provide a description of commonly observed artifacts in scanning tunneling microscopy (STM) and atomic force microscopy (AFM) relating to probe motion and geometric considerations of the tip and surface interaction, provide literature references of examples and, where possible, to offer an interpretation as to the source of the artifact. Because the scanned probe microscopy field is a burgeoning one, this document is not meant to be comprehensive but rather to serve as a guide to practicing microscopists as to possible pitfalls one may expect. The ability to recognize artifacts should assist in reliable evaluation of instrument operation and in reporting of data. 1.2 A limited set of terms will be defined here. A full description of terminology relating to the description, operation, and calibration of STM and AFM instruments is beyond the scope of this document. 1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. |
||
2. Referenced Documents | ||
|
Historická
15.11.2013
Historická
1.12.2010
Historická
15.11.2013
Historická
15.11.2013
Historická
1.1.2012
Historická
1.10.2009
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.