Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications
Přeložit název
NORMA vydána dne 15.6.2021
Označení normy: ASTM E2232-21
Datum vydání normy: 15.6.2021
Kód zboží: NS-1030398
Počet stran: 19
Přibližná hmotnost: 57 g (0.13 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
benchmarking, deterministic method, discrete ordinates, empirical method, mathematical models, modeling, modelling, Monte Carlo, point kernel, radiation processing, radiation transport, stochastic, validation, verification,, ICS Number Code 07.020 (Mathematics),17.240 (Radiation measurements)
Significance and Use | ||||||||||
4.1?Use as an Analytical ToolMathematical methods provide an analytical tool to be employed for many applications related to absorbed dose determinations in radiation processing. Mathematical calculations may not be used as a substitute for routine dosimetry in some applications (for example, medical device sterilization, food irradiation). 4.2?Dose CalculationAbsorbed-dose calculations may be performed for a variety of photon/electron environments and irradiator geometries. 4.3?Evaluate Process EffectivenessMathematical models may be used to evaluate the impact of changes in product composition, loading configuration, and irradiator design on dose distribution. 4.4?Complement or Supplement to DosimetryDose calculations may be used to establish a detailed understanding of dose distribution, providing a spatial resolution not obtainable through measurement. Calculations may be used to reduce the number of dosimeters required to characterize a procedure or process (for example, dose mapping). 4.5?Alternative to DosimetryDose calculations may be used when dosimetry is impractical (for example, granular materials, materials with complex geometries, material contained in a package where dosimetry is not practical or possible). 4.6?Facility DesignDose calculations are often used in the design of a new irradiator and can be used to help optimize dose distribution in an existing facility or radiation process. The use of modeling in irradiator design can be found in Refs (2-7). 4.7?ValidationThe validation of the model should be done through comparison with reliable and traceable dosimetric measurements. The purpose of validation is to demonstrate that the mathematical method makes reliable predictions of dose and other transport quantities. Validation compares predictions or theory to the results of an appropriate experiment. The degree of validation is commensurate with the application. Guidance is given in the documents referenced in Annex A2. 4.8?VerificationVerification is the confirmation of the mathematical correctness of a computer implementation of a mathematical method. This can be done, for example, by comparing numerical results with known analytic solutions or with other computer codes that have been previously verified. Verification should be done to ensure that the simulation is appropriate for the intended application. Refer to 3.1.24. Note 2:?Certain applications of the mathematical model deal
with Operational Qualification (OQ), Performance Qualification (PQ)
and process control in radiation processing such as the
sterilization of healthcare products. The application and use of
the mathematical model in these applications may have to meet
regulatory requirements. Refer to Section 6 for prerequisites for application of a
mathematical method and Section 8 for requirements before routine use of
the mathematical method.
4.9?UncertaintyAn absorbed dose prediction should be accompanied by an estimate of overall uncertainty, as it is with absorbed-dose measurement (refer to ISO/ASTM 51707 and JCGM100:2008 and JCGM200:2012). In many cases, absorbed-dose measurement helps to establish the uncertainty in the dose calculation. 4.10?This guide should not be used as the only reference in the selection and use of mathematical models. The user is encouraged to contact individuals who are experienced in mathematical modelling and to read the relevant publications in order to select the best tool for their application. Radiation processing is an evolving field and the references cited in the annotated examples of Annex A6 are representative of the various published applications. Where a method is validated with dosimetry, it becomes a benchmark for that particular application. |
||||||||||
1. Scope | ||||||||||
1.1?This guide describes different mathematical methods that may be used to calculate absorbed dose and criteria for their selection. Absorbed-dose calculations can determine the effectiveness of the radiation process, estimate the absorbed-dose distribution in product, or supplement or complement, or both, the measurement of absorbed dose. 1.2?Radiation processing is an evolving field and annotated examples are provided in Annex A6 to illustrate the applications where mathematical methods have been successfully applied. While not limited by the applications cited in these examples, applications specific to neutron transport, radiation therapy and shielding design are not addressed in this document. 1.3?This guide covers the calculation of radiation transport of electrons and photons with energies up to 25 MeV. 1.4?The mathematical methods described include Monte Carlo, point kernel, discrete ordinate, semi-empirical and empirical methods. 1.5?This guide is limited to the use of general purpose software packages for the calculation of the transport of charged or uncharged particles and photons, or both, from various types of sources of ionizing radiation. This standard is limited to the use of these software packages or other mathematical methods for the determination of spatial dose distributions for photons emitted following the decay of 137Cs or 60Co, for energetic electrons from particle accelerators, or for X-rays generated by electron accelerators. 1.6?This guide assists the user in determining if mathematical methods are a useful tool. This guide may assist the user in selecting an appropriate method for calculating absorbed dose. The user must determine whether any of these mathematical methods are appropriate for the solution to their specific application and what, if any, software to apply. Note 1:?The user is urged to apply these predictive techniques
while being aware of the need for experience and also the inherent
limitations of both the method and the available software.
Information pertaining to availability and updates to codes for
modeling radiation transport, courses, workshops and meetings can
be found in Annex A1. For a
basic understanding of radiation physics and a brief overview of
method selection, refer to Annex
A3.
1.7?This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.8?This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee. |
||||||||||
2. Referenced Documents | ||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 04.11.2024 (Počet položek: 2 209 323)
© Copyright 2024 NORMSERVIS s.r.o.