Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Test Method for Determination of Total Carbon in Mold Powders by Combustion-Infrared Absorption Spectrometry
Automaticky přeložený název:
Standardní zkušební metoda pro stanovení celkového uhlíku v Mold prášků Combustion - infračervené absorpční spektrometrie
NORMA vydána dne 15.1.2012
Označení normy: ASTM E2050-12
Poznámka: NEPLATNÁ
Datum vydání normy: 15.1.2012
Kód zboží: NS-44111
Počet stran: 4
Přibližná hmotnost: 12 g (0.03 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
carbon, combustion, infrared absorption spectrometry, mold powders, Carbon content--metals/alloys, Combustion infrared absorption spectrometry, Infrared (IR) analysis--metals/alloys, Mold powders, Spectrometry, Total carbon (TC), ICS Number Code 83.080.01 (Plastics in general)
Significance and Use | ||||||||||||||
This test method for the determination of total carbon in mold powders is primarily intended to test such materials for compliance with compositional specifications. It is assumed that all who use this test method will be trained analysts capable of performing common laboratory procedures skillfully and safely. It is expected that the work will be performed in a properly equipped laboratory and that proper waste disposal procedures will be followed. Appropriate quality control practices must be followed such as those described in Guide E882. |
||||||||||||||
1. Scope | ||||||||||||||
1.1 This test method covers the determination of total carbon in mold powders in the concentration range from 1 % to 25 %. Note 1—As used in this test method, “percentage” or “%” refers to a mass fraction of the form (wt / wt %) (g/100g). 1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.3 This test method has been evaluated in accordance with Practice E1601 and Guide E1763. Unless otherwise noted in the precision and bias section, the lower limit in the scope of each method specifies the lowest analyte content that may be analyzed with acceptable error (defined as a nominal 5 % risk of obtaining a 50 % or larger relative difference in results on the same test sample in two laboratories). 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||
2. Referenced Documents | ||||||||||||||
|
Chcete mít jistotu, že používáte pouze platné technické normy?
Nabízíme Vám řešení, které Vám zajistí měsíční přehled o aktuálnosti norem, které používáte.
Chcete vědět více informací? Podívejte se na tuto stránku.
Poslední aktualizace: 15.11.2024 (Počet položek: 2 210 820)
© Copyright 2024 NORMSERVIS s.r.o.