Potřebujeme váš souhlas k využití jednotlivých dat, aby se vám mimo jiné mohly ukazovat informace týkající se vašich zájmů. Souhlas udělíte kliknutím na tlačítko „OK“.
Standard Method for Estimating Kinetic Parameters by Differential Scanning Calorimeter Using the Borchardt and Daniels Method
Automaticky přeložený název:
Standardní metoda pro odhad kinetických parametrů diferenční skenovací kalorimetru Použití Borchardt a Daniels metoda
NORMA vydána dne 1.10.2003
Označení normy: ASTM E2041-03
Poznámka: NEPLATNÁ
Datum vydání normy: 1.10.2003
Kód zboží: NS-44079
Počet stran: 9
Přibližná hmotnost: 27 g (0.06 liber)
Země: Americká technická norma
Kategorie: Technické normy ASTM
Keywords:
activation energy, Arrhenius frequency factor, Borchardt and Daniels kinetics, differential scanning calorimetry (DSC), kinetics, pre-exponential factor, reactions, ICS Number Code 17.200.10 (Heat. Calorimetry)
Significance and Use | ||||||||||||||||||||
This test method is useful in research and development., The determination of the appropriate model for a chemical reaction or transformation and the values associated with its kinetic parameters may be used in the estimation of reaction performance at temperatures or time conditions not easily tested. This use, however, is not described in this test method. |
||||||||||||||||||||
1. Scope | ||||||||||||||||||||
1.1 This test method describes the determination of the kinetic parameters of activation energy, Arrhenius pre-exponential factor, and reaction order using the Borchardt and Daniels treatment of data obtained by differential scanning calorimetry. This test method is applicable to the temperature range from 170 to 870 K (100 to 600°C). 1.2 This treatment is applicable only to smooth exothermic reactions with no shoulders, discontinuous changes, or shifts in baseline. It is applicable only to reactions with reaction order n 2. It is not applicable to autocatalyzed reactions and, therefore, is not applicable to the determination of kinetic parameters for most thermoset curing reactions or to crystallization reactions. 1.3 Electronic instrumentation or automated data analysis systems or treatments equivalent to this test method may be used. Note 1—The user is advised that all electronic data treatment may not be equivalent. It is the responsibility of the user of such electronic data treatment to verify applicability to this test method. 1.4 SI values are the standard. 1.5 This test method is similar, but not equivalent to, ISO Method 11357, Part 5, which contains provisions for additional information not supplied by this test method. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. |
||||||||||||||||||||